PATON
ProMIG
DC MMA/TIG/MIG/MAG
- 38 -
7. GENERAL LIST AND SEQUENCE OF FUNCTIONS
MMA WELDING MODE
0) [-1-] Main displayed parameter CURRENT = 90A (default)
a) 8 ... 160А (step of change 1А) for РroMIG
-160
b) 10...200А (step of change 1А) for РroMIG
-200
c) 12...250А (step of change 1А) for РroMIG
-250
d) 12 ... 270А (step of change 1А) for РroMIG
-270
e) 14...350А (step of change 1А) for РroMIG
-350
f) 16 ... 500А (step of change 1А) for РroMIG
-500
g) 18...630А (step of change 1А) for РroMIG
-630
1) [H.St] Hot Start Power = 40% (default)
a) 0[OFF] ... 100% (step of change 5%)
2) [t.HS] Hot Start Time = 0.3 sec (default)
a) 0,1 ... 1,0 s (step of change 0.1 sec)
3) [Ar.F] Arc Power = 40% (default)
0 [OFF] ... 100% (step change 5%)
4) [u.AF] Arc Force Trigger level = 12V (default)
a) 9 ... 18V (step change 1V)
5) [CVS] Slope of the current-voltage characteristic = 1.4V/A (default)
a) 0.2...1.8V/A (step change 0.4V/A)
6) [Sh.A] Short arc welding = OFF (default)
a) ON
–
activated
b) OFF - deactivated
7) [BSn] Voltage reduction unit = OFF (default)
a) ON
–
activated
b) OFF - deactivated
8) [Po.P] Current pulse power = OFF (default)
a) ON
–
activated
b) OFF - deactivated
9) [I.iP] Base current = 90A (default)
a) 8 ... 160А (step of change 1А) for РroMIG
-160
b) 10...200А (step of change 1А) for РroMIG
-200
c) 12...250А (step of change 1А) for РroMIG
-250
d) 12 ... 270А (step of change 1А) for РroMIG
-270
e) 14...350А (step of change 1А) for РroMIG
-350
f) 16 ... 500А (step of change 1А) for РroMIG
-500
g) 18...630А (step of change 1А) for РroMIG
-630
10) [I.PS] Pauze current = 90A (default)
a) 8 ... 160А (step of change 1А) for РroMIG
-160
b) 10...200А (step of change 1А) for РroMIG
-200
c) 12...250А (step of change 1А) for РroMIG
-250
d) 12 ... 270А (step of change 1А) for РroMIG
-270
e) 14...350А (step of change 1А) for
РroMIG
-350
f) 16 ... 500А (step of change 1А) for РroMIG
-500
g) 18...630А (step of change 1А) for РroMIG
-630
Summary of Contents for PROMIG-160