PATON
ProMIG
DC MMA/TIG/MIG/MAG
- 40 -
7) [I.iP] Peak current = 100A (default)
a) 8 ... 160А (step of change 1А) for РroMIG
-160
b) 10...200А (step of change 1А) for РroMIG
-200
c) 12...250А (step of change 1А) for РroMIG
-250
d) 12 ... 270А (step of change 1А) for РroMIG
-270
e) 14...350А (step of change 1А) for РroMIG
-350
f) 16 ... 500А (step of change 1А) for РroMIG
-500
g) 18...630А
(step of change 1А) for РroMIG
-630
8) [u.PS] Base current = 100A (default)
a) 8 ... 160А (step of change 1А) for РroMIG
-160
b) 10...200А (step of change 1А) for РroMIG
-200
c) 12...250А (step of change 1А) for РroMIG
-250
d) 12 ... 270А
(step of
change 1А) for РroMIG
-270
e) 14...350А (step of change 1А) for РroMIG
-350
f) 16 ... 500А (step of change 1А) for РroMIG
-500
g) 18...630А (step of change 1А) for РroMIG
-630
9) [Fr.P] Current pulse frequency = 10.0 Hz (default)
a) 0.2...500 Hz (degree of dynamic variation 0.1 Hz...1 Hz)
10) [dut] Pulse/pause ratio (duty cycle) - this is the percentage of the current pulse within
the repetition period of these pulses = 50% (default)
a) 20...80% (rate of change 5%)
MIG/MAG Welding Mode
Left source indicator
0) [-3-] Main display VOLTAGE parameter = 19.0V (default)
a) 12...24V
(step of change 0.1V) for РroMIG
-160
b) 12...26V
(step of change 0.1V) for РroMIG
-200
c) 12...28V
(step of change 0.1V) for РroMIG
-250
d) 12...29V
step of change 0.1V) for Рro
MIG-270
e) 12...30V
(step of change 0.1V) for РroMIG
-350
f) 12...40V
(step of change 0.1V) for РroMIG
-500
g) 12...44V
(step of change 0.1V) for РroMIG
-630
1) [But] Torch button mode = [2T] (by default)
a) [2T] - 2T torch button mode
b) [4T] - 4T torch standard button mode
c) [alt.4T] - 4T torch alternative button mode
2) [Ind] Inductance = OFF (default)
а)
0 [OFF] ... step 3 (step of change 1)
3) [t.Pr] Shielding gas pre-flow time = 0.1 sec (default)
a) 0.1 ... 25.0 sec (step of change 0.1 sec)
Summary of Contents for PROMIG-160