Revised May 1, 2019
Revision 25 of DOCU225, © Copyright
Page 20 of 44
Element
Function
WITS In All
On the RMPC, use this tab to set up incoming WITS codes for all
Pason computers connected to WITS devices.
WITS Out RMPC
On the RMPC, use this tab to set up WITS codes being sent to
devices connected to the RMPC.
WITS Out TPC Server
On the RMPC, use this tab to set up WITS codes being sent to
devices connected to the TPC server.
WITS Out DHC/SideKick
On the RMPC, use this tab to set up WITS codes being sent to
devices connected to the DHC or SideKick.
WITS Out Operator
On an Operator Workstation, use this tab to set up WITS codes
being sent to devices connected to the Operator Workstation. This
feature is only available on US Operator Workstations. To see this
tab, the operator must have WITS editing privileges for the well.
WITS Out Workstation
On a Workstation, use this tab to set up WITS codes being sent to
devices connected to the Workstation.
WITS Monitor
Diagnostic tool for troubleshooting.
Transmission
and
Interval
These settings are used together to determine the period between
sent WITS codes. They apply to all the WITS codes in the group
you select. Use the Transmission drop-down list to select the type
of transmission the interval is based on. Depending on which
WITS record group you are in, you can choose Time Based, Depth
Based, or Request-Response.
Time Based
means that the Pason computer you are configuring
sends the record group’s enabled WITS codes at the time interval
you select.
Depth Based
means that the Pason computer you are configuring
sends the record group’s enabled WITS codes at the depth
interval you select.
Request-Response
means that the Pason computer you are
configuring sends the record group’s enabled WITS codes only
when a response is requested by a third-party WITS device.
Use the Interval drop-down list to select a time- or depth-based
interval.