Revised May 1, 2019
Revision 25 of DOCU225, © Copyright
Page 24 of 44
7. For each of your selections, enter the following information:
•
Code
: Enter a WITS code for the trace by clicking under Code in the trace's
row. If the code you enter conflicts with a code already in use, the EDR
displays an error message in the Status Message box and doesn't allow you
to save the changes.
•
Units
: Click under Unit in the trace's row and choose the units from the drop-
down list. Note that these are display units only—the EDR doesn't perform
conversions based on the units you select.
•
Data Summary
: If you've chosen a depth or time-based transmission type,
use the Data Summary drop-down list to select how the EDR calculates the
WITS value.
8. When you are finished configuring, click
Save
>
Exit
to return to the Setup Menu.
4.6 Configuring Custom WITS in the EDR
If you need to send or receive data not listed in the table of
on page 32, you must set up a custom WITS code. Once a custom WITS code is set up,
the EDR can receive it from any connected WITS device, but you need to follow the
steps in
Selecting Custom WITS Codes to Send
on page 27 to instruct a Pason
computer to send custom WITS codes.
Setting up Custom WITS Codes
To set up a custom WITS code, use the following procedure:
1. From the EDR main screen on the RMPC, click
Menu
>
Setup
>
WITS
. The
WITS
setup
screen opens.
2. On the WITS In All tab, click the
Custom
button. The Custom WITS setup screen
opens. This screen displays 50 editable custom WITS codes, names, units,
adjustable decimal spaces, and shelf lives.