81
13.2 Triple-Lok
®
assembly instructions
Tools for Parflange
®
machines
Any use of unsuitable, damaged or worn tools may result in failure of the screw
connections and damage to the assembly device
Tools must be inspected regularly, and no later than following 50 assemblies
Any worn tools must be replaced
Only use original Parker tools
Keep tools clean and lubricate them regularly
•
Clean the flaring pin for
inspection
•
Visual
inspection: The
surface must
not feature any
wear or
damage
•
Clean the clamping jaws
for inspection
Do not dismantle the tools
•
Locking pins may
not be
loose or damaged
•
Visual
inspection:
Spanner flats
must not
feature any
wear or
deposits
•
Remove any metal
abrasion with a metal
brush
Adjustment of Parflange
®
tools
•
Undo the screw to reduce
the flaring diameter
(counter-clockwise)
Adjust both screws
at the same time
1 click
≅
approx. 0.05 mm Ø
•
Tighten the screw to
increase the flaring
diameter
(clockwise)
Set both screws
consistently
1 click
≅
approx. 0.05 mm Ø
•
Adjust stop
screws in
small steps
•
Check the flaring
diameter
Secure screws from
twisting out of position
The correct flaring diameter can be set at the Parflange
®
clamping jaws
Basic machine problems cannot be rectified by adjusting the clamping jaws (tube stop
worn, loose screw connections)