13.1 O-Lok
®
assembly instructions
Flange Seal
Mechanical flaring and assembly
•
Safe method
•
Efficient procedure
•
Use the Parflange
®
process
Parflange
®
1025
Parflange
®
machine:
•
Select flaring pin in
accordance with tube
dimensions
•
Use standard O-Lok®
flaring pin
•
The flaring pin must not
feature any wear and tear,
damage or contaminants
•
Keep the flaring pin clean
and lubricate it regularly
•
Select the clamping jaws in
accordance with the tube
dimensions
•
Use the special clamping
jaws for the flange seal
•
The clamping surfaces must
not feature any wear and tear
or abrasion
•
Only use original Parker
tools for O-Lok®
Observe limits for max. tube
wall thickness
•
Insert flaring pin in tool holder
•
Ensure that the automatic
lubricating unit is filled with
EONIROMONTFLUESSX or
LUBSS
•
Slide the nut over the
tube end and place the
support sleeve in the
clamping jaw half
•
Fit the clamping jaw
halves together
•
Insert the closed jaw
set into the conical
Insert the tube end until the
stop point
•
Clamp the tube
•
Secure the tube
•
Activate
Do not reach into the
operating area
•
Open the clamping lever
•
Remove tube end from the
machine with clamping jaws
•
Loosen the jaws in the
separator by moving the tube
sideways