60
1.3 Hazards and hazard prevention
Safe work at the machine requires interaction between the machine, controls, tools,
safety devices and safety-conscious conduct by the users. Most accidents with machines
result in injuries as a result of closing tools. These essentially result in injuries to the
fingers and hands. There is also a risk of injury for individuals other than the machine
operator.
1.4 Usage in accordance with the intended purpose
Parflange
®
1025 is used for the assembly of Triple-Lok
®
and O-Lok
®
screw connection
systems. Tubes with the sizes
-
OD 6 to 25 mm / 1/4´ to 1´
are the only ones that may be used for the joining process. Only those raw materials and
tube qualities may be used that meet the requirements of the latest Parker TFDE -
Catalogue 4100 in the “Tube specifications” section.
Usage of the Parflange
®
1025 in accordance with its intended purpose requires that the
machine is only used within the scope of the options stated in the technical specifications
and is only operated in perfect condition.
Any other usage may be dangerous and exclude any further services. The manufacturer is
not liable for damage or injury caused by improper operation.
1.5 Tools in accordance with the intended purpose
Only those EO tools specially developed for this machine may be used for assembly with
the Parflange
®
1025. The tools must be inspected on a regular basis. Any tools that
feature clear traces of wear and tear must be replaced by the machine operator. The
operator is under an obligation only to use suitable tools that are produced in accordance
with our specifications, particularly in relation to
-
material
-
heat treatment
-
geometry
1.6 improper use
1. Any usage that differs from that stated above is not permitted, as hazards may arise
from improper use which may result in injury to those individuals working on or in
the vicinity of the device or may cause damage to the device itself.
2. Known and foreseeable improper use:
-
Forcing in of machine parts, e.g. bearings/sockets
-
Use of inappropriate tools
-
Processing of materials that are not suitable for forming