105
Motor access
See maintenance sheet A 10
Motor upgrade
Loosen the 4 motor fastening screws
(A)
.
Replace the motor and rewire.
Check for correct belt tension (sag of
less than 10 mm). Adjust the setting
with the screws
(B)
if necessary
.
Work on electrical components
should only be carried out by
expert staff. The machine must
be disconnected from the
electrical supply before work
takes place on electrical
components.
Maintenance sheet
Number
Index
Parflange 1025
Page
FIP025GB004 01
1/1
Motor replacement A 40 - page 36
A 40
1H00
Rewire the motor power supply with/as
with the thermal contact cable
(see sheet
A 10
).