5-12
Installation - Control Module
AC30 series Variable Speed Inverter
APPLICATION 1: AUTO/MANUAL CONTROL
Ideal for automatic control applications with limit switches or proximity transducers
ANIN 01
(X11/01)
ANIN 02
(X11/02)
RAMP
0486
Acceleration Time
MANUAL SETPOINT
AUTO SETPOINT
RUNNING
NOT
TRIPPED
CURRENT LIMIT
V/F SHAPING
CT
VT
V
F
PWM CONTROL
I FDBK
F
V
F
V
MANUAL RUN
AUTO SELECT
REVERSE
NOT COAST STOP
NOT QUICKSTOP
TRIP RESET
AUTO RUN
0422
Vhz Shape
0457
Base Frequency
0447
Fixed Boost
0455
Rated Motor Current
FEEDBACKS
ANOUT 01
(X11/03)
ANOUT 02
(X11/04)
SPEED DEMAND
MOTOR CURRENT
Application 1:
“Auto/Manual Control”
IDEAL FOR AUTOMATIC CONTROL
APPLICATIONS WITH LIMIT SWITCHES OR
PROXIMITY TRANSDUCERS
AUTOMATIC
Pump
Auto / Manual Selector
Auto
Speed
Reference
Level
Limit
Switch
Level Sensor
LEVEL CONTROL
REF SELECT
RUN SELECT
FWD / REV
0484
Seq Stop Method
SEQUENCING LOGIC
DIGIN 01
(X13/02)
DIGIN 02
(X13/03)
DIGIN 03
(X13/04)
DIGIN 04
(X12/01)
DIGIN 05
(X12/02)
DIGIN 06
(X12/03)
DIGIN 07
(X12/02)
MIN /MAX SPEED
1264
Ref Min Speed Clamp
1265
Ref Max Speed Clamp
0487
Deceleration Time
0504
Stop Ramp Time
0508
Quickstop Ramp Time
RELAY 01
(X14/01)
(X14/02)
RELAY 02
(X14/03)
(X14/04)
RELAY 11
(X23/01)
(X23/02)
if AC30V
Requires IO Option
7004-01-00
RELAY 12
(X23/03)
(X23/04)
if AC30V
Requires IO Option
7004-01-00
OR
OR
Auto/Manual Control Application
Two Run inputs and two Setpoint inputs are provided. The Auto/Manual switch selects which pair of inputs is active.
The Application is sometimes referred to as Local/Remote.
Summary of Contents for LINKnet AC30P
Page 4: ...AC30 series Variable Speed Inverter...
Page 16: ...2 4 Introduction AC30 series Variable Speed Inverter...
Page 22: ...3 6 Product Overview AC30 series Variable Speed Inverter...
Page 55: ...Installation Control Module 5 17 AC30 series Variable Speed Inverter Presets Speeds Wiring...
Page 57: ...Installation Control Module 5 19 AC30 series Variable Speed Inverter PID Control Wiring...
Page 68: ...5 30 Installation Control Module AC30 series Variable Speed Inverter...
Page 82: ...6 14 Associated Equipment Power Stack AC30 series Variable Speed Inverter...
Page 86: ...7 4 Associated Equipment Control Module AC30 series Variable Speed Inverter...
Page 124: ...9 8 The Graphical Keypad AC30 series Variable Speed Inverter...
Page 126: ...10 2 Routine Maintenance Repair AC30 series Variable Speed Inverter...
Page 152: ...A 26 Compliance AC30 series Variable Speed Inverter...
Page 166: ...E 8 Technical Specifications Power Stack AC30 series Variable Speed Drive...
Page 175: ...AC30 series Variable Speed Drive...