Chapter 2 – Installation
17
AC Power Connections
GT6K-L5/L8 and
GV6K-L3n: Connecting AC Power
CAUTION
Do not operate GV6K-L3n above 132VAC, or the drive will be permanently dam-
aged.
120VAC Operations:
1.
Connect power system’s safety earth to drive’s protective conductor terminal,
marked with the
symbol. Do not fuse the protective conductor terminal.
2.
Connect 120VAC, 50/60 Hz, single phase power line to drive’s L1 and N terminals.
3.
Reinstall the clear plastic terminal cover after you make connections
.
Connections are illustrated in the next drawing.
GT6K-L5/L8;
GV6K-L3n at 120VAC
95 – 132VAC
GV6K-U3n/6n/12n
at 120/240VAC
VBUS–
L2/N
L1
95 – 264VAC
Fuses
N/C
N
L1
Fuses
Drive terminals: #8
(M4).
Mating terminals:
spade fork, 0.325"
maximum width.
Tightening torque: 20 in-lbs nominal,
24 in-lbs max.
Power Connections – GT6K and GV6K-L3/U3/U6/U12
GV6K-U3n/6n/12n: Connecting AC Power
Connections are illustrated in the drawing above.
208/240VAC Operations:
1.
Connect power system’s safety earth to drive’s protective conductor terminal,
marked with the
symbol. Do not fuse the protective conductor terminal.
2.
Connect 208/240VAC, 50/60 Hz, single phase power to drive’s L1 and L2/N
terminals.
3.
Reinstall the clear plastic terminal cover after you make connections.
120VAC Operations:
1.
Connect power system’s safety earth to drive’s protective conductor terminal,
marked with the
symbol. Do not fuse the protective conductor terminal.
2.
Connect 120VAC, 50/60 Hz, single phase power line to drive’s L1 terminal.
3.
Connect neutral to drive’s L2/N terminal.
4.
Reinstall the clear plastic terminal cover after you make connections.