Drive Controlled Pump
Parker Hannifin Corporation
Hydraulics Group
DCP Manual innen A4 UK.indd 06.11.17
57
Manual
RUNTIME ERROR
CODE 00000000
Runtime Alerts
A Runtime Alert is a fault that indicates a permanent
hardware error. The Runtime Alert display is of the form
CODE is a number in the range 0 to 65000. The following
value is used to provide additional information to assist
Parker Hannifin Technical Support personnel.
CODE
ERROR
Possible Reason for Error
1 to
255
Internal exception
· VCM not secured to power stack
· Option not secured correctly to VCM control card
· Earth bonding failure.
· Fault during firmware upgrade
12
Memory access
· Attempt to read or write to protected memory. Most likely this will be due to a configuration
error. Press OK several times until the drive resets correctly, then replace the configuration
using PDQ.
· Record the error message and contact Technical Support
1001 to
1003
Processor overload
· Select a lower switching frequency, (Parameters::Motor Control::Pattern Generator::Stack
Frequency)
· Record the error message and contact Technical Support
1006
Memory overflow
· Reduce the complexity of the application
· Reduce the number of parameters being accessed via the on board Modbus TCP protocol
· Reduce the number of parameters being accessed by the fieldbus communications option.
1007
Uninitialized pointer
· Record the error message and contact Technical Support
1010
Initialization error
· Record the error message and contact Technical Support
1101 to
1111
1200 to
1299
Communications option
error
· Ensure the communications option is correctly fitted
· Update the firmware in the AC30.
· Replace the communications option
1300
Ethernet fault
· Record the error message and contact Technical Support
1301
Modbus server
· Record the error message and contact Technical Support
1302
HTTP server fault
· Record the error message and contact Technical Support
1303
DCT server fault
· Record the error message and contact Technical Support
1401
Control Module test
· Control module self-test error
1402
1403
Power stack test
· VCM not secured to power stack
1404
· Power stack self-test error
1501
IO Option identity
· Ensure the IO option is correctly fitted
1502
IO Option processor
· Update the firmware in the AC30.
1503
Unknown IO Option
· Replace the IO option
1502
IO Option processor
· Ensure the IO option is correctly fitted
· Update the firmware in the AC30.
· Replace the IO option
1503
Unknown IO Option
· Ensure the IO option is correctly fitted
· Update the firmware in the AC30.
· Replace the IO option
1504
IO Option watchdog
· The IO Option has become disconnected
1601
Stack internal fault
· Return the power stack to Parker Hannifin repair center.