Drive Controlled Pump
Parker Hannifin Corporation
Hydraulics Group
DCP Manual innen A4 UK.indd 06.11.17
49
Manual
Menu item
Monitor::Application::Testfunction
PNO
2034
2035
2036
2040
Parameter name
DIGIN05 Pump2
DIGIN04 Switch On
DIGIN05 Switch Off
Testmovement
Parameter
description
Select pump 2
Switch On pressure Accumu-
lator control
Switch Off pressure Accumu-
lator control
Testmovement
Function
Simulating of DIN05. Via this
parameter, pump 2 can be
turned on or off.
It can be used for a double
pump only.
This parameter is only used
for testing.
Simulating of DIN04, if the Ac-
cumulator Control is active. Via
this parameter, the “Switch On
Pressure” can be simulated.
This parameter is only used
for testing.
Simulating of DIN05, if the Ac-
cumulator Control is active. Via
this parameter. the “Switch Off
Pressure” can be simulated.
This parameter is only used
for testing.
This parameter will start the
test movement. External set-
points for Q and p will be in-
gnored.
Settings for the test movement
are made in the parameters
2041 to 2045.
Menu item
Monitor::Application::Testfunction
PNO
2030
2031
2032
2033
Parameter name
DIGIN01 Start
DIGIN02 No Stop
DIGIN03 Reset
DIGIN04 Pump1
Parameter
description
Start
No Stop
Reset error
Select pump 1
Function
Simulating of DIN01. Via this
parameter, the drive can be
started without setting DIN01.
This parameter is only used
for testing.
Simulating of DIN02. Via this
parameter, the drive can be
set to “No Stop” without set-
ting DIN02.
This parameter is only used
for testing.
Simulating of DIN03. Via this
parameter, the actual error of
the drive can be resetted.
This parameter is only used
for testing.
Simulating of DIN04. Via this
parameter, pump 1 can be
turned on or off. It can be used
for a double pump only.
This parameter is only used
for testing.
Settings Testfunction
Menu item
Monitor::Application::Testfunction
PNO
2041
2042
2043
2044
Parameter name
P1 Testmovement
P2 Testmovement
Q1 Testmovement
Q2 Testmovement
Parameter
description
Pressure 1 Testmovement
Pressure 2 Testmovement
Flow 1 Testmovement
Flow 1 Testmovement
Function
Target-pressure 1 for the
test movement. The pres-
sure ramps [bar/s] are taken
over from the setup of the p-
Control.
Target-pressure 2 for the
test movement. The pres-
sure ramps [Bar/s] are taken
over from the setup of the p-
Control.
Target-Flow 1 for the test
movement. The ramps are
depending on the motor
ramps.
Target-Flow 2 for the test
movement. The ramps are
depending on the motor
ramps.
Menu item
Monitor::Application::
Testfunction
PNO
2045
Parameter name
Time Testmovement
Parameter
description
Time Testmovement
Function
Waiting time between pres-
sure 1 and pressure 2 or flow
1 and flow 2.
Settings Component Protection
Menu item
Setup::Application:: Component Protection
PNO
2050
Parameter name
Component Protection
Parameter
description
Component Protection
Function
This value is used to protect the motor and pump
from overheating at min. speed. After the elapsed
time at min. speed, the drive stopps. If the time is
set to 0s, the function is switched off.
Settings Trip Status
Menu item
Monitor::Quick Monitor
PNO
2051
Parameter name
Trip Status
Parameter
description
Trip Status
Function
This value displays the actual error status.