Drive Controlled Pump
Parker Hannifin Corporation
Hydraulics Group
DCP Manual innen A4 UK.indd 06.11.17
52
Manual
PNO
Name
Path(s)
Type
Default
Range
Units
WQ
Selected
App
1938 Max p sensor p0
Setup::Application::Analog Input Q
REAL
0
0 to 500
BAR
ALWAYS
ALL
Setup::Application::Analog Input p
Setup::Application::Analog Input pQ
Setup::Application::Analog Input LS
Setup::Application::Analog Input Accu
1939
Pressure reached p,LS
Control
WARNING
BOOL FALSE
NEVER
p , LS
Monitor::Application::Digital IOs
1940 Pressure reached pQ
Monitor::Application::Digital IOs
BOOL FALSE
NEVER
pQ
1941 Min outlet pressure
REAL
0
0 to 100
BAR
ALWAYS
1942 Upper Limit pressure
Setup::Application::p Control
REAL
0
0 to 500
BAR
ALWAYS p, p/Q. LS
Setup::Application::p/Q Control
Setup::Application::LS Control
1946 Pressure Switch Mode Setup::Application::Accu Control
BOOL FALSE
ALWAYS
Accu
1947 Sensor Mode On
Monitor::Application::Status Accu Con-
trol
BOOL FALSE
NEVER
Accu
1948 Switch Mode On
Monitor::Application::Status Accu Con-
trol
BOOL FALSE
NEVER
Accu
1949 Switch On pressure
Setup::Application::Accu Control
REAL
0
0 to 500
BAR
ALWAYS
Accu
1950 Switch Off pressure
Setup::Application::Accu Control
REAL
0
0 to 500
BAR
ALWAYS
Accu
1951 Count T short warning
INT
0
ALWAYS
1952 Count T short error
INT
0
ALWAYS
1953 T min OnOff control
TIME
0
S
ALWAYS
1954 Actual Count time short
INT
0
ALWAYS
1955 Accu min pump speed
INT
0
RPM
ALWAYS
1960 Delta p Setpoint
Setup::Application::LS Control
REAL
0
0 to 500
BAR
ALWAYS
LS
1961 Actual delta p LS
Monitor::Application::Status LS Control REAL
0
0 to 500
BAR
NEVER
LS
1962 Actual pressure LS
Monitor::Application::Status LS Control REAL
0
0 to 500
BAR
NEVER
LS
1963 Max p Sensor LS
Setup::Application::LS Control
REAL
0
0 to 500
BAR
ALWAYS
LS
1968 Pressure Controller Kp
Monitor::Application::p Control
REAL
0,001
0 to 100
%/BAR ALWAYS p, p/Q, LS
Monitor::Application::p/Q Control
Monitor::Application::LS Control
1969 Pressure Controller Ki
Monitor::Application::p Control
REAL
0,001
0 to 100
%/BAR ALWAYS p, p/Q, LS
Monitor::Application::p/Q Control
Monitor::Application::LS Control
1970 Pressure Controller Kd
Monitor::Application::p Control
REAL
0
0 to 100
%/BAR ALWAYS p, p/Q, LS
Monitor::Application::p/Q Control
Monitor::Application::LS Control
1971 Controller Output
Monitor::Application::p Control
REAL
0
-100 to 100
%
NEVER p, p/Q, LS
Monitor::Application::p/Q Control
Monitor::Application::LS Control
1972 Tracking Error
Monitor::Application::p Control
REAL
0
0 to 500
BAR
NEVER p, p/Q, LS
Monitor::Application::p/Q Control
Monitor::Application::LS Control
1973 Inner window Ipart
Monitor::Application::p Control
REAL
0
0 to 500
BAR
ALWAYS p, p/Q, LS
Monitor::Application::p/Q Control
Monitor::Application::LS Control
1974 Outer window Ipart
Monitor::Application::p Control
REAL
300
0 to 500
BAR
ALWAYS p, p/Q, LS
Monitor::Application::p/Q Control
Monitor::Application::LS Control
1975 Pos. Limit Ki
Monitor::Application::p Control
REAL
100
0.000 to 10.000
s
ALWAYS p, p/Q, LS
Monitor::Application::p/Q Control
Monitor::Application::LS Control
1976 Neg. Limit Ki
Monitor::Application::p Control
REAL
-100
0 to 100
%
ALWAYS p, p/Q, LS
Monitor::Application::p/Q Control
Monitor::Application::LS Control
1977 Rate Feedback
Monitor::Application::p Control
REAL
0
-10 to 10
%
ALWAYS p, p/Q, LS
Monitor::Application::p/Q Control
Monitor::Application::LS Control