6 Options
980-001-0240B
FrameSaver NP 110 User’s Manual - Installation Guide
6-39
November 2000
Backup Setup - Selects the current state for backup operations.
Selections are as follows:
Reset/Arm - Terminates any current activity and clears any Failed or Disabled
conditions so that automatic backup initiation may occur. This is the
default state.
Activate -Initiates backup connection process.
Service Disable -Terminates and/or disables all backup activity to prevent
initiation of undesired backup while preforming service activity. Disable
is automatically released to the Reset/Arm state after 15 continuous
minutes of no service activity detected (service activity is indicated by
the existence of fault conditions or tests such as Red Alarm, Line
Loopback, etc.).
Time Disable - Terminates and/or disables all backup activity for the specified
period of time. When selected, a prompt is displayed to select the time
period (1 to 72 hours). After valid time period is entered, the “Duration”
field is displayed, showing the time remaining before Disable is
released to the Reset/Arm state.
User Ckt Status -
RTS/DTR/LL: State of lead when Power is being detected from the DTE.
States are: ON or OFF.
Pwr: ON or OFF based on sensing voltage on Tx data lead(s) from the DTE.
Frame Fault: Blank or highest priority Frame Fault disrupting the data path.
Refer to the Appendix in this manual for a list and description of all fault dis-
plays.
ISDN - Displays (blank) or the current state of the ISDN Adapter and Backup
status, as reported by the ISDN Adapter module. Status states are:
ISDN Adp Fault - The ISDN hardware has failed (backup cannot
be accomplished).
Primary Online - Backup connection in place using Primary Dials.
Secondary Online - Backup connection in place using Secondary Dials.
Primary DwnSpd - Backup connection in place using Primary Dials, but
with fewer ISDN connections than configured for.
Secondary DwnSpd - Backup connection in place using Secondary
Dials, but with fewer ISDN connections than configured for.
Connecting - Connection is being established.
Failed - Retry attempts exhausted.
ISDN Line Failure - The ISDN line of at least one B-Channel is faulty
(backup may not be possible).
ISDN SPID Failure - An invalid or incorrect SPID has been entered for at
least one B-Channel (backup may not be possible).
B1 SPID Failure - A B2-Channel cannot operate due to a SPID failure
on its associated B1-Channel.
Service Disabled - “Service Disable” has been selected on the
“ISDN Status / Test” screen.
Time Disabled - “Time Disable” has been selected on the
“ISDN Status / Test” screen.
LoopUp - LoopUp connection in place.
Armed - Default state if not disabled and no failure exists.