6 Options
980-001-0240B
FrameSaver NP 110 User’s Manual - Installation Guide
6-15
November 2000
Device Status/Test
The Device Status / Test screen provides DSX and Drop port status and test capability.
The Device Status/Test screen is shown in Figure 6-9.
Figure 6-9 Device Status/Test Screen
Name - Device’s ID as defined in unit’s Device Configuration.
Facility ID - Network Facility ID as defined in unit’s CSU Interface Configuration.
Netw Port Fault - Status detected by the Network Port.
External Set Test - Indicates status when unit is in loopback due to an external acti-
vation.
Ckt Under Test - Selects circuit to be tested. Setting reverts to “Network” at logout.
NOTE: Changes to this setting while a selected test is active will force the test to
be cleared without any warning. Changes to this setting will not affect an
External Set Test.
Test Mode - When the “Ckt Under Test” selection is DSX or Drop, allows selection
of one of the test modes shown in Table 6-4.
***************************** Device Status / Test *****************************
Name: F@43802
Netw Port Fault: Facility ID: NONAME
External Set Test:
Test Mode [T=]
Ckt Under Test [C=] >>1) Clear<<
>>1) Network<< 2) Line Lp to Netw
2) User 3) Payld Lp to Netw
3) DSX 4) Send LoopUp
4) Drop 5) Send LoopDn
6) QRSS to Netw
User Ckt Status 7) Alt Ones to Netw
RTS/DTR/LL/Pwr: On /On /Off//On 8) 2047 to Netw
Frame Fault: 9) Zero to Netw
DSX Port Fault: 10) Line Lp to CPE
Drop Port RTS/DTR/LL: On /On /Off
BERT: Blocks Sent: , , Block Errors: , , BlkErr Rate: 0.00E+00
Test Duration: 00:00:00
ResetTest[RT] InjectErr[IE secs] RebootExt[RE secs]
Help[?] Close[X] AutoUpdate[AU]
>