5 Diagnostics
5-6
NetPath 110 User’s Manual - Installation Guide
980-001-0240B
November
2000
User Ckt Status - Displays current status being detected by CSU.
States (in highest priority order) are:
RTS:State of RTS lead, when Power is being detected from the DTE.
States are: ON or OFF.
DTR:State of DTR lead, when Power is being detected from the DTE.
States are: ON or OFF.
LL: State of LL lead, when Power is detected from the DTE.
States are: ON or OFF.
Pwr: ON or OFF based on sensing voltage on Tx data lead(s) from the DTE.
Frame Fault - Displays (blank) or the highest priority Fault causing a disruption of the
data path.
Refer to the Appendix in this manual for a list and description of all fault
displays.
Commands:
ResetTest [RT] - Resets BERT or PVC result counters without disrupting the test
operation and refreshes all dynamic information contained on the screen.
InjectErr [IE secs] - Injects a single bit error into the BERT stream. When issued
without the “secs,” a single bit error will be injected at execution of this command.
When issued with a “secs” value between 1 - 255, a single bit error will be injected
once a second for the number of “secs” entered (user can issue other commands while
this takes place in background).
RebootExt [RE secs] - Used to interrupt AC Power to the DTE device connected to
the Switched AC Output connector on the rear of the unit, thereby forcing the de-
vice to reboot. When issued with a “secs” parameter, power will remain off for the
specified length of time (1 - 300 seconds). When issued as “RE” only, power will
be interrupted for five seconds at the execution of this command.
Help [?] - Advances to “Help” for Device Status / Test screen.
Close [X] - Returns to System View screen.
AutoUpdate [AU] - Provides automatic screen update and refresh (every five sec-
onds) of all status and Test (when active) results. No changes can be made while in this
mode, and the bottom lines on the screen are replaced as shown in Figure 5-4. AutoUp-
date is exited by pressing ENTER.
Figure 5-4 Auto Update Screen Change
---> Screen updates every 5 seconds <---
---> Press Enter for Command Prompt <---