Commands:
ResetTest [RT] - Resets BERT or PVC result counters without disrupting the test
operation and refreshes all dynamic information contained on the screen.
InjectErr [IE secs] - Injects a single bit error into the BERT stream. When issued
without the “secs,” a single bit error will be injected at execution of this command.
When issued with a “secs” value between 1 - 255, a single bit error will be injected
once a second for the number of “secs” entered (user can issue other commands while
this takes place in background).
RebootExt [RE secs] - Causes power to be interrupted to the DTE device connected
to the Switched AC Output connector on the rear of the unit. When issued without
the “secs,” power will be interrupted for five seconds at execution of this com-
mand. When issued with a “secs” value between 1 - 30, power will remain off for
the number of seconds entered.
Help [?] - Advances to “Help” for Device Status / Test screen.
Close [X] - Returns to System View screen.
AutoUpdate [AU] - Provides automatic screen update and refresh (every five sec-
onds) of all status and Test (when active) results. No changes can be made while in this
mode, and the bottom lines on the screen are replaced as shown in Figure 6-10. Au-
toUpdate is exited by pressing ENTER.
Figure 6-10 Auto Update Screen Change
---> Screen updates every 5 seconds <---
---> Press Enter for Command Prompt <---