4 Operation
980-001-0240B
FrameSaver NP 110 User’s Manual - Installation Guide
4-19
November
2000
PVC Performance
Configuration
The PVC Performance Configuration Screen allows you to view and alter parameters
for Network Performance measurement operations on a per-PVC basis.
The PVC Performance Configuration Screen is shown in Figure 4-8.
Figure 4-8 PVC Performance Configuration Screen
1. Page - Selects one page of the indicated number to display.
2. Desired Delay Mon Rate - Setting for the rate at which a Delay measurement
packet is injected on each PVC in the list specified at the bottom of this screen.
Default value (10) dictates that within each 10-second period, every PVC on the
list is measured once. A PVC’s packet is considered lost if it does not return before
a subsequent packet is injected on that PVC. The packet send rate cannot exceed
10 per second.
NOTE: FrameSaver NP 110 Delay measurement packets are 36 bytes in length,
when issued. A FrameSaver NP looping (receiving and returning) a Delay
measurement packet will add two additional bytes to the packet.
3.
Min Pkts for Delay Alarm - Setting for the number of packets that must be
received within the current interval on a PVC before the “PVC Delay Thres”
average is considered a valid check for that PVC. If the number is not reached
within the interval, that PVC cannot cause the alarm condition to be declared or
maintained, based on the average of the packets received.
************************* PVC Performance Configuration ************************
Name: F@43802
Page [P=#]: 1 of 6
Desired Delay Mon Rate [R=#]: 10 Drpd Mon Pkt Thres [L=#]: Disabled
X to Disable or 1 thru 240 Seconds X to Disable or 1 thru 895 pkts
Min Pkts for Delay Alarm [C=#]: 10 PVC Delay Thres [T=#]: Disabled
3 thru 895 pkts X to Disable or 10 thru 9000 mSecs
Desired Loss Mon Rate [S=#]: 60 PVC Dlvd Pkt Thres [G=#]: Disabled
X to Disable or 60 thru 240 Seconds X to Disable or 10 thru 99 %
"LMI" CIR Values [V=] Interval Period [I=#]: 15
>>1) Use<< 1 to 15 minutes
2) Ignore
CIR Bins [B=#,#,#,#,#,#]: 25,35,50,71,100,141 (1 thru 200 %)
Auto: TxCIR[A1=#]:0 RxCIR[A2=#]:0 Mon [AM=None,Dlay,Loss,orBoth]: None
Manual: TxCIR[M1=#]:0 RxCIR[M2=#]:0 Mon [MM=None,Dlay,Loss,orBoth]: Dlay
0 thru 1536 Kbs
AddPVC [A=#] DeletePVC [D=#] ([A=m,n,...r) and/or [A=m-n] for multiple entries)
PVC,TxCR,RxCR,Mon PVC,TxCR,RxCR,Mon PVC,TxCR,RxCR,Mon PVC,TxCR,RxCR,Mon
Help[?] Save[SA] Cancel[X]
>