Path - Selects WAN (W) or Payload/CPE (P) as the management path for sending
traps to the corresponding Trap Manager.
CAUTION
Trap Manager addresses must be unique across both
WAN and P/C Networks. Out-of-band traps are sent to all
trap managers assigned to one of the two paths. The AC
power loss trap is sent to the first trap manager in the list
with a valid IP address.
2. Disable Traps - Selects Traps to be disabled. Can be selected individually, or in
groups. Selected (disabled) items are bracketed by “>>”..... “<<” characters as
shown in item #1 on the example screen above.
3. Clear Holdoff - Sets the number of minutes that a trap condition must remain
clear, before it is declared clear.
4. Terminate Delay - Sets the time a Dial-Out connection will remain in place after
the last Out-of-Band Trap was sent, to permit exchange of additional PDUs
(Protocol Data Units).
Commands:
Help [?] - Advances to “Help” for SNMP Community Access Configuration screen.
Save [SA] - Saves parameters and returns to System View screen.
Cancel [X] - Returns to System View screen without saving changes.
Save the SNMP Trap Manager Configuration changes when they are all set correctly
by entering “SA” followed by ENTER. This will also return the user to the System
View screen.
Proceed to PVC Configuration, selecting [PC] by typing “PC” followed by ENTER.