Monitoring and Testing
4-29
3166-A2-GB20-20
March 1999
3. From the Patterns screen, select Abort.
F1
Patterns:
Abort
Send
Mon
F2
F3
4. From the Patterns Abort screen, press the desired Function key to abort
either All active test patterns, active Send test patterns, or the active Monitor
(Mon) test pattern.
F1
Patterns: Abort
All
Send
Mon
F2
F3
If you select All, the DSU/CSU terminates all active test patterns and displays
the message
Command Complete
. Skip Step 5.
NOTE:
If you mistakenly choose to abort a test pattern that is not currently
running, a
Command Complete
message still displays and the test
pattern currently active still runs. Use the TStat branch to view the test
status to determine if the abort was successful.
5. From the Abort screen, press the Function key that corresponds to the
interface for which you want to abort a test pattern. Use the scroll keys, if
necessary.
F1
Abort:
Send or Mon
NET
Prt1
F2
F3
The DSU/CSU terminates the selected test pattern and displays the message
Command Complete
.
Summary of Contents for 3166 DSU
Page 1: ...ACCULINK 3166 DSU CSU USER S GUIDE Document No 3166 A2 GB20 20 March 1999...
Page 16: ...About This Guide x 3166 A2 GB20 20 March 1999 This page intentionally left blank...
Page 20: ...Introduction 1 4 3166 A2 GB20 20 March 1999 This page intentionally left blank...
Page 68: ...SDCP Operation 3 42 3166 A2 GB20 20 March 1999 This page intentionally left blank...
Page 102: ...SDCP Menu A 2 3166 A2 GB20 20 March 1999 This page intentionally left blank...
Page 140: ...Pin Assignments D 12 3166 A2 GB20 20 March 1999 This page intentionally left blank...
Page 166: ...SNMP MIB Objects E 26 3166 A2 GB20 20 March 1999 This page intentionally left blank...
Page 192: ...Equipment List I 2 3166 A2 GB20 20 March 1999 This page intentionally left blank...