Monitoring and Testing
4-9
3166-A2-GB20-20
March 1999
Table 4-3.
Performance Registers (3 of 3)
Register
Totals Description
Interval Description
StEvnt
(Only valid
for User
registers.)
The status events register records
whether one or more of the
following events have occurred at
least once during the interval. The
event is identified by a letter as
follows:
Y – A Yellow Alarm signal has
been received on the network
interface.
L – Loss Of Signal has occurred
on the DTE Drop/Insert
(DSX-1) interface.
E – The Excessive Error Rate
threshold has been
exceeded.
F – A Frame Synchronization Bit
Error has been detected.
If none of these events occurred
during the interval,
StEvnt=none
will be displayed.
N/A
Complete
(Only valid
for far-end
port
registers.)
Bad line conditions or loopback
tests may prevent far-end port
statistics from reaching the
DSU/CSU. This field indicates
whether the 15-minute interval
contains 900 seconds of statistics.
If one or more seconds of far-end
statistics are missing, this field will
display
Complete=No
, otherwise it
will display
Complete=Yes
. This
field is only displayed when Far is
selected from the Prt1 screen.
N/A
Summary of Contents for 3166 DSU
Page 1: ...ACCULINK 3166 DSU CSU USER S GUIDE Document No 3166 A2 GB20 20 March 1999...
Page 16: ...About This Guide x 3166 A2 GB20 20 March 1999 This page intentionally left blank...
Page 20: ...Introduction 1 4 3166 A2 GB20 20 March 1999 This page intentionally left blank...
Page 68: ...SDCP Operation 3 42 3166 A2 GB20 20 March 1999 This page intentionally left blank...
Page 102: ...SDCP Menu A 2 3166 A2 GB20 20 March 1999 This page intentionally left blank...
Page 140: ...Pin Assignments D 12 3166 A2 GB20 20 March 1999 This page intentionally left blank...
Page 166: ...SNMP MIB Objects E 26 3166 A2 GB20 20 March 1999 This page intentionally left blank...
Page 192: ...Equipment List I 2 3166 A2 GB20 20 March 1999 This page intentionally left blank...