Monitoring and Testing
4-20
3166-A2-GB20-20
March 1999
Starting a Line Loopback
The Line Loopback command (LLB) loops the received signal on the network
interface back to the network without change.
98-15946
CSU
DSU
NETWORK
INTERFACE
ALL 1s
LLB
PORT 1
Procedure
To perform a Line loopback:
1. From the top-level menu screen, select Test.
2. From the Test screen, select Lpbk.
F1
Test:
Rlpbk Lpbk
Ptrns
F2
F3
3. From the Loopback screen, select LLB.
F1
Loopback:
Abort
LLB
PLB
F2
F3
Test Started
appears on Line 2. If a Line loopback is already in progress,
the
Already Active
message appears. If an invalid combination of
loopbacks is in progress, the error message
Invld Test Combo
appears
(see
Table 4-7
for valid loopback test combinations).