Monitoring and Testing
4-11
3166-A2-GB20-20
March 1999
Alarms
The DSU/CSU can be attached, either locally or remotely, to an ASCII terminal or
printer to display or print alarm messages. Alarms can also be displayed on a PC
that is using a terminal emulation package.
You can route these alarms to the COM port or dial them out using an external
device.
Each alarm message contains a customer identification to indicate which remote
DSU/CSU is reporting an alarm. For information about customer identification,
refer to
Displaying Unit Identity
in Chapter 3,
SDCP Operation.
Possible alarm messages are as follows:
Continuous Loss Of Signal detected at the
Network
Interface.
Alarm Cleared. Loss Of Signal condition at the
Network
Interface.
Continuous Out Of Frame condition detected at the Network
Interface.
Alarm Cleared. Out Of Frame condition at the
Network
Interface.
Alarm Indication Signal received at the Network
Interface.
Alarm Cleared. Alarm Indication Signal at the Network
Interface.
An Excessive Error Rate has been detected at the Network
Interface
.
Alarm Cleared. An Excessive Error Rate at the Network
Interface
.
Yellow Alarm signal received at the Network Interface
.
Alarm Cleared. Yellow Alarm signal at the
Network
Interface
.
Continuous Out Of Frame condition detected at synchronous
data port 1.
Alarm Cleared. Out Of Frame condition at synchronous data
port 1.
An Excessive Error Rate has been detected at synchronous
data port 1.
Alarm Cleared. An Excessive Error Rate at synchronous
data port 1.
Summary of Contents for 3166 DSU
Page 1: ...ACCULINK 3166 DSU CSU USER S GUIDE Document No 3166 A2 GB20 20 March 1999...
Page 16: ...About This Guide x 3166 A2 GB20 20 March 1999 This page intentionally left blank...
Page 20: ...Introduction 1 4 3166 A2 GB20 20 March 1999 This page intentionally left blank...
Page 68: ...SDCP Operation 3 42 3166 A2 GB20 20 March 1999 This page intentionally left blank...
Page 102: ...SDCP Menu A 2 3166 A2 GB20 20 March 1999 This page intentionally left blank...
Page 140: ...Pin Assignments D 12 3166 A2 GB20 20 March 1999 This page intentionally left blank...
Page 166: ...SNMP MIB Objects E 26 3166 A2 GB20 20 March 1999 This page intentionally left blank...
Page 192: ...Equipment List I 2 3166 A2 GB20 20 March 1999 This page intentionally left blank...