SDCP Operation
3-39
3166-A2-GB20-20
March 1999
Acquiring/Releasing the User Interface
You can access the user interface from either the the COM port or the SDCP. The
DSU/CSU allows only one user interface to be active at a time. The COM port is
the default user interface at power-up or after a reset. It is also the default during
a software download or when a failure occurs at either the local or remote PC
interface.
You can switch an inactive user interface to active if:
The current active user interface has had no activity (no key was pressed) for
at least five minutes.
The active user interface has been released with the Release command of
the Control branch.
The active interface connection is broken. This includes the termination of the
front panel emulation program on a locally attached PC (if the PC supports
DTR) or the termination of the Asynchronous Terminal Interface on a remote
or locally attached terminal.
Acquiring the Active User Interface
To acquire the active user interface, press any key. If you are using the PC
interface, use the mouse to click on the desired Function key. The top-level menu
screen appears on the active user interface, regardless of what screen was
displayed at the previous active user interface.
F1
DSU ESF
Stat
Test
Cnfig
F2
F3
The inactive interface displays an interface active message when a Function key
is pressed or a connection is made on the inactive user interface and control
cannot be switched because the currently active interface is in use. On the
screen, either Com Port or SDCP is shown as active. For example:
F1
DSU ESF
Com Port active
F2
F3
Summary of Contents for 3166 DSU
Page 1: ...ACCULINK 3166 DSU CSU USER S GUIDE Document No 3166 A2 GB20 20 March 1999...
Page 16: ...About This Guide x 3166 A2 GB20 20 March 1999 This page intentionally left blank...
Page 20: ...Introduction 1 4 3166 A2 GB20 20 March 1999 This page intentionally left blank...
Page 68: ...SDCP Operation 3 42 3166 A2 GB20 20 March 1999 This page intentionally left blank...
Page 102: ...SDCP Menu A 2 3166 A2 GB20 20 March 1999 This page intentionally left blank...
Page 140: ...Pin Assignments D 12 3166 A2 GB20 20 March 1999 This page intentionally left blank...
Page 166: ...SNMP MIB Objects E 26 3166 A2 GB20 20 March 1999 This page intentionally left blank...
Page 192: ...Equipment List I 2 3166 A2 GB20 20 March 1999 This page intentionally left blank...