Spectra Series
11
24 = Special Alarm
00 = Emergency Panic
01 = Auxiliary Panic
02 = Fire Panic
03 = Recent Closing
04 = Auto Zone Shutdown
05 = Duress Alarm
99 = Any Sub-Group
25 = Auto Zone Shutdown
01-16 = Zones 1 to 16
99 = Any Zone
26 = Zone Tamper
01-16 = Zones 1 to 16
99 = Any Zone
27 = Zone Tamper Restore
01-16 = Zones 1 to 16
99 = Any Zone
28 = System Trouble
01 = AC Loss: only after
Power Failure Delay
has elapsed
(
Partition 1 only
)
02 = Battery Failure (
Partition 1 only
)
03 = Auxiliary current overload (
Partition 1 only
)
04 = Bell current overload (
Partition 1 only
)
05 = Bell disconnected (
Partition 1 only
)
06 = Timer Loss (
Partition 1 only
)
07 = Fire Loop Trouble (
Partition 1 only
)
08 = Wireless Transmitter Low Battery (
Partition 1 only
)
09 = Module Fault (
Partition 1 only
)
10 = Printer Fault (
Partition 1 only
)
11 = Fail to Communicate (
Partition 1 only
)
99 = Any Sub-Group (
Partition 1 only
)
29 = System Trouble Restore
00 = TLM restore (
Partition 1 only
)
01 = AC Loss restore (
Partition 1 only
)
02 = Battery Failure restore (
Partition 1 only
)
03 = Auxiliary current overload restore (
Partition 1 only
)
04 = Bell current overload restore (
Partition 1 only
)
05 = Bell disconnected restore (
Partition 1 only
)
06 = Timer Programmed (
Partition 1 only
)
07 = Fire Loop Trouble restore (
Partition 1 only
)
08 = Wireless Transmitter Low Battery restore (
Partition 1 only
)
09 = Module Fault restore (
Partition 1 only
)
10 = Printer Fault restore (
Partition 1 only
)
11 = Fail to Communicate restore (
Partition 1 only
)
99 = Any Trouble Restore (
Partition 1 only
)
30 = Special Reporting
00 = System Power Up (
Partition 1 only
)
01 = Test Report (
Partition 1 only
)
02 = WinLoad Software Access (
Partition 1 only
)
03 = WinLoad Software Access finish (
Partition 1 only
)
04 = Installer enters programming mode (
Partition 1 only
)
05 = Installer exits programming mode (
Partition 1 only
)
99 = Any Sub-Group (
Partition 1 only
)
31 = Wireless Transmitter Supervi-
sion Loss
01-16 = Zones 1 to 16
99 = Any Zone
32 = Wireless Transmitter Supervi-
sion Loss Restore
01-16 = Zones 1 to 16
99 = Any Zone
Event Group #