18   

Programming Guide

PROGRAMMABLE - ADEMCO CONTACT ID REPORT CODE LIST

If using the Ademco Contact ID Programmable code format, enter the 2-digit hexadecimal value from the table below 

(Prog.

Value)

 into sections [160] to [213] to program the desired report codes. 

To enter a 0 value press the [

FORCE

] key.

CID#

Reporting

 Prog.

Code

Value

CID#

Reporting

 Prog.

Code

Value

CID#

Reporting

 Prog.

Code

Value

MEDICAL ALARMS - 100

204

Low Water Level

2F

403

Automatic O/C

5D

100

Medical Alarm

01

205

Pump Activated

30

404

Late to O/C

5E

101

Pendant Transmitter

02

206

Pump Failure

31

405

Deferred

5F

102

Fail to Report In

03

SYSTEM TROUBLES - 300 & 310

406

Cancel

60

FIRE ALARMS - 110

300

System Trouble

32

407

Remote Arm/Disarm

61

110

Fire Alarm

04

301

AC Loss

33

408

Quick Arm

62

111

Smoke

05

302

Low System Battery

34

409

Keyswitch O/C

63

112

Combustion

06

303

RAM Checksum Bad

35

REMOTE ACCESS - 410

113

Water Flow

07

304

ROM Checksum Bad

36

411

Callback Request Made

64

114

Heat

08

305

System Reset

37

412

Success - Download Access

65

115

Pull Station

09

306

Panel Program Changed

38

413

Unsuccessful Access

66

116

Duct

0A

307

Self-Test Failure

39

414

System Shutdown

67

117

Flame

0B

308

System Shutdown

3A

415

Dialer Shutdown

68

118

Near Alarm

0C

309

Battery Test Failure

3B

ACCESS CONTROL - 420

PANIC ALARMS - 120

310

Ground Fault

3C

421

Access Denied

69

120

Panic Alarm

0D

SOUNDER/RELAY TROUBLES - 320

422

Access Report By User

6A

121

Duress

0E

320

Sounder Relay

3D

SYSTEM DISABLES - 500 & 510

122

Silent

0F

321

Bell 1

3E

SOUNDER RELAY DISABLES - 520

123

Audible

10

322

Bell 2

3F

520

Sounder/Relay Disabled

6B

BURGLAR ALARMS - 130

323

Alarm Relay

40

521

Bell 1 Disable

6C

130

Burglary

11

324

Trouble Relay

41

522

Bell 2 Disable

6D

131

Perimeter

12

325

Reversing

42

523

Alarm Relay Disable

6E

132

Interior

13

SYSTEM PERIPHERAL TROUBLES - 330 & 340

524

Trouble Relay Disable

6F

133

24-Hour

14

330

System Peripheral

43

525

Reversing Relay Disable

70

134

Entry/Exit

15

331

Polling Loop Open

44

SYSTEM PERIPHERAL DISABLES - 530 & 540

135

Day/Night

16

332

Polling Loop Short

45

COMMUNICATION DISABLES - 550 & 560

136

Outdoor

17

333

Exp. Module Failure

46

551

Dialer Disabled

71

137

Tamper

18

334

Repeater Failure

47

552

Radio xmitter Disabled

72

138

Near Alarm

19

335

Local Printer Paper Out

48

BYPASSES - 570

GENERAL ALARMS - 140

336

Local Printer Failure

49

570

Zone Bypass

73

140

General Alarm

1A

COMMUNICATION TROUBLES - 350 & 360

571

Fire Bypass

74

141

Polling Loop Open

1B

350

Communication 

4A

572

24-Hour Zone Bypass

75

142

Polling Loop Short

1C

351

Telco Fault 1

4B

573

Burg. Bypass

76

143

Expansion Module Failure

1D

352

Telco Fault 2

4C

574

Group Bypass

77

144

Sensor Tamper

1E

353

Long Range Radio

4D

TEST/MISC. - 600

145

Expansion Module Tamper

1F

354

Fail to Communicate

4E

601

Manual Trigger Test

78

24-HOUR NON-BURGLARY - 150 & 160

355

Loss of Radio Supervision

4F

602

Periodic Test Report

79

150

24-Hour Non-Burglary

20

356

Loss of Central Polling

50

603

Periodic RF Xmission

7A

151

Gas Detected

21

PROTECTION LOOP TROUBLES - 370

604

Fire Test

7B

152

Refrigeration

22

370

Protection Loop

51

605

Status Report to Follow

7C

153

Loss of Heat

23

371

Protection Loop Open

52

606

Listen-in to Follow

7D

154

Water Leakage

24

372

Protection Loop short

53

607

Walk Test Mode

7E

155

Foil Break

25

373

Fire Trouble

54

621

Event Log Reset

7F

156

Day Trouble

26

SENSOR TROUBLES - 380

622

Event Log 50% Full

80

157

Low Bottled Gas Level

27

380

Sensor Trouble

55

623

Event Log 90% Full

81

158

High Temp

28

381

Loss of Super. -RF

56

624

Event Log Overflow

82

159

Low Temp

29

382

Loss of Super. - RPM

57

625

Time/Date Reset

83

161

Loss of Air Flow

2A

383

Sensor Tamper

58

626

Time/Date Inaccurate

84

FIRE SUPERVISORY - 200 & 210

384

RF xmtr. Low Battery

59

627

Program Mode Entry

85

200

Fire Supervisory

2B

OPEN/CLOSE - 400

628

Program Mode Exit

86

201

Low Water Pressure

2C

400

Open/Close

5A

631

Exception Schedule Change

87

202

Low CO2

2D

401

O/C by User

5B

203

Gate Valve Sensor

2E

402

Group O/C

5C

Summary of Contents for Spectra 1725

Page 1: ...PROGRAMMING GUIDE SPECTRA CONTROL PANELS V1 2 1725 1725EX 1728 AND 1728EX 1755 1755EX 1758 AND 1758EX...

Page 2: ......

Page 3: ...RT CODES 16 Arming Report Codes 16 Disarming Report Codes 16 Alarm Report Codes 17 Tamper Report Codes 17 System Trouble Report Codes 17 Programmable Ademco Contact ID Report Code List 18 All Codes Ad...

Page 4: ...ypass Recall Feature 33 One Touch Arming 33 Keyswitch Arming 33 Panic Alarms 33 Auto Arming 34 Alarm Memory Display 34 Programming Chime Zones 34 Keypad Muting 34 Quick Function Keys 34 HARDWARE CONNE...

Page 5: ...Spectra Series 3...

Page 6: ...ctions 001 to 016 127 to 138 302 to 348 610 650 to 651 After entering the programming mode as described in the shaded box above each option from 1 to 8 will represent a specific feature or option Pres...

Page 7: ...ote controls see page 28 Download to DESTINATION Control Panel 1 Remove AC and battery power from the control panel 2 Insert the Memory Key onto the serial connector labeled KEY on the Spectra control...

Page 8: ...odule or Z1 to Z8 of the SPC ZX8 module represent expansion inputs 1 to 8 respectively Please note that the module s inputs must be enabled in section 651 of the control panel Refer to Zone Assignment...

Page 9: ...____ ____ ____ 1 2 3 4 5 6 7 8 010 Zone 10 ____________________ ____ ____ 1 2 3 4 5 6 7 8 011 Zone 11 ____________________ ____ ____ 1 2 3 4 5 6 7 8 012 Zone 12 ____________________ ____ ____ 1 2 3 4...

Page 10: ...2 45 sec 071 ___ ___ ___ seconds EXIT DELAY 1 30 sec 072 ___ ___ ___ seconds EXIT DELAY 2 30 sec 073 ___ ___ ___ minutes 000 no bell on alarm BELL CUT OFF TIME PARTITION 1 4 min 074 ___ ___ ___ minute...

Page 11: ...6 Zones 1 to 16 99 Any Zone 02 Partition Status 00 System not ready Partition 1 only 01 System ready Partition 1 only 02 Steady Alarm in Partition 03 Pulsed Alarm in Partition 04 Pulsed or Steady Alar...

Page 12: ...to Close auto arming failed 02 No Movement Auto Arming 03 Partial Arming stay force instant bypass 04 One Touch Arming 05 Arm with WinLoad Software 06 Arm with Keyswitch 99 Any Sub Group 15 Disarm wi...

Page 13: ...re Partition 1 only 01 AC Loss restore Partition 1 only 02 Battery Failure restore Partition 1 only 03 Auxiliary current overload restore Partition 1 only 04 Bell current overload restore Partition 1...

Page 14: ...d 2 Tamper Supervision l Disabled l Enabled SECTION 129 General Options Option OFF ON 1 PGM2 Output Activation Option l Steady l Pulse flash 2 PGM2 Pulse Once Every 30sec If System Armed l Disabled l...

Page 15: ...s l No 8 Normal State of Global PGM l Normally Closed N C l Normally Open SECTION 132 Zone Options Option OFF ON 1 2 l see table l see table l see table l see table 3 Generate Tamper if detected on By...

Page 16: ...ure Use l N A l N A SECTION 136 Dialer Options Option OFF ON 1 Call Back l Disabled l Enabled 2 Automatic Event Buffer Transmission l Disabled l Enabled 3 Contact I D Report Codes l Programmable l All...

Page 17: ...__ __ __ __ __ __ __ __ CENTRAL STATION TELEPHONE OR PAGER NUMBER 1 32 DIGITS if less than 32 press ENTER to accept 152 __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __...

Page 18: ...ode 37 __ __ Access code 38 __ __ Access code 39 __ __ Access code 40 170 __ __ Access code 41 __ __ Access code 42 __ __ Access code 43 __ __ Access code 44 171 __ __ Access code 45 __ __ Access code...

Page 19: ...12 200 __ __ Zone 13 __ __ Zone 14 __ __ Zone 15 __ __ Zone 16 RESTORE 201 __ __ Zone 1 __ __ Zone 2 __ __ Zone 3 __ __ Zone 4 202 __ __ Zone 5 __ __ Zone 6 __ __ Zone 7 __ __ Zone 8 203 __ __ Zone 9...

Page 20: ...m Peripheral 43 525 Reversing Relay Disable 70 134 Entry Exit 15 331 Polling Loop Open 44 SYSTEM PERIPHERAL DISABLES 530 540 135 Day Night 16 332 Polling Loop Short 45 COMMUNICATION DISABLES 550 560 1...

Page 21: ...n by user Disarm after alarm with Keyswitch 1 4A9 Keyswitch Open Auto Arming Cancellation 1 4A5 Deferred Open Close Disarm with PC software 1 4A7 Remote arm disarm Disarm after an alarm with PC softwa...

Page 22: ...Low Battery 3 384 RF xmtr low battery Wireless Transmitter Supervision Loss 3 381 Loss of super RF Module fault restore 3 333 Expansion module failure restore Printer fault restore 3 336 Local printe...

Page 23: ...ser Code 018 1 2 3 4 5 6 7 8 319 User Code 019 1 2 3 4 5 6 7 8 320 User Code 020 1 2 3 4 5 6 7 8 321 User Code 021 1 2 3 4 5 6 7 8 322 User Code 022 1 2 3 4 5 6 7 8 323 User Code 023 1 2 3 4 5 6 7 8 3...

Page 24: ..._EXPANSION INPUT 1 602 ___ ___ ___ ___ ___ ___EXPANSION INPUT 2 603 ___ ___ ___ ___ ___ ___EXPANSION INPUT 3 604 ___ ___ ___ ___ ___ ___EXPANSION INPUT 4 605 ___ ___ ___ ___ ___ ___EXPANSION INPUT 5 6...

Page 25: ...ts will appear one at a time by illuminating the corresponding light To view the next digit press the ENTER key On LCD keypads the entire serial number will appear on the screen STEP 4 Return to STEP...

Page 26: ...ng of 3 characters and up is acceptable Section Description 631 Display Signal Strength of Expansion Input 1 Section 601 632 Display Signal Strength of Expansion Input 2 Section 602 633 Display Signal...

Page 27: ...sion Module Tamper Recognition l Disabled l Z1 becomes tamper input 3 PGM1 on Zone Expansion Module follows Global PGM programmed in sections 124 125 l Disabled l Enabled 4 Future Use l N A l N A 5 Fu...

Page 28: ...vate 100mS after any of the above events have occurred if programmed RESET ZONE EXPANSION MODULE 660 PRESS ENTER TO CONFIRM WILL RESET THE ZONE MODULE S SECTIONS 650 TO 657 TO DEFAULT VALUES Event Gro...

Page 29: ...TE CONTROL 1 A B C D A B C D A C B D 712 ____ ____ ____ ____ ____ ____ ____ ____ REMOTE CONTROL 2 A B C D A B C D A C B D 713 ____ ____ ____ ____ ____ ____ ____ ____ REMOTE CONTROL 3 A B C D A B C D A...

Page 30: ...E CONTROL TWICE YOU WILL HEAR A CONFIRMATION BEEP REMOTE CONTROL 4 735 PRESS A BUTTON ON A REMOTE CONTROL TWICE YOU WILL HEAR A CONFIRMATION BEEP REMOTE CONTROL 5 736 PRESS A BUTTON ON A REMOTE CONTRO...

Page 31: ...Bell Current The BELL output uses a fuseless circuit and will automatically shut down if the current exceeds 3A with a 1725 1725EX 1728 or 1728EX or 2 5A with a 1755 1755EX 1758 or 1758EX After openin...

Page 32: ...ssigned to partition 1 Master Code 2 is permanently assigned to partition 2 except when partitioning is disabled Master Code 2 will be assigned to partition 1 and can be used to create modify or delet...

Page 33: ...d If you make a mistake the keypad will emit a REJECTION BEEP When you have correctly Stay Armed the system the appropriate ARM indication will appear and the Exit Delay will be initiated Stay Arming...

Page 34: ...emit a REJECTION BEEP When correctly Force Armed the appropriate ARM indication will appear and the Exit Delay will be initiated Please note that Force Arming can also be activated using One Touch Fo...

Page 35: ...ress and hold the ENTER button for 3 seconds The system will switch to Exit Delay mode At the end of the Exit Delay period the control panel will switch to Regular Arming To Exit and Force Arm Press a...

Page 36: ...on Enter the 2 digit 01 to 16 zone number s When the corresponding LED is on the zone is chimed When the corresponding LED is off the zone is unchimed When the desired zones are chimed press ENTER LCD...

Page 37: ...Spectra Series 35 HARDWARE CONNECTIONS SINGLE ZONE INPUTS DOUBLE ZONE INPUTS with ATZ option only...

Page 38: ...36 Programming Guide CONNECTING A KEYSWITCH CONNECTING FIRE CIRCUITS PGM CONNECTIONS...

Page 39: ...Spectra Series 37 CONNECTING A LIBERATOR WIRELESS BUS MODULE SPC 319 CONNECTING A ZONE EXPANSION MODULE SPC ZX8...

Page 40: ...38 Programming Guide SPECTRA 1725 1725EX 1728 AND 1728EX PCB LAYOUT...

Page 41: ...river Option Only An optional siren driver is available with the Spectra 1755 1755EX 1758 and 1758EX control panels This siren driver allows you to connect speakers directly to the bell output as show...