34
Programming Guide
AUTO-ARMING
You can program the
Spectra
alarm panel to automatically arm at a specific time everyday or if no movement is detected for a
specified period of time. The user is only allowed to program the Auto Arm Timer.
Please note that the control panel will enter a 60-
second Exit Delay period before arming the system. At this point, Auto-Arming can be cancelled by entering a valid access code.
ALARM MEMORY DISPLAY
A record of all alarm situations that occur will be stored in memory. After disarming the system, pressing the
[
MEM
]
button will
display which zones were in alarm during the last armed period. To exit the
Alarm Memory Display
, press the
[
CLEAR
]
button.
The control panel will erase the contents of the alarm memory every time the system is armed.
PROGRAMMING CHIME ZONES
This feature allows users to program which zones will be
"Chime Enabled"
. A
"Chime Enabled"
zone will cause the keypad to
emit a rapid intermittent beep tone (
BEEP
-
BEEP
-
BEEP
-
BEEP
) advising the user every time it is opened. Each keypad must be
Chime Programmed separately. Keypad chimes must be re-programmed if the system suffers a total power loss.
10-Zone LED Keypad:
Press and hold any button from
[1]
to
[10]
for 3 seconds to activate or deactivate
Chiming
for zones 1 to 10. For example,
press and hold the [1] button to enable chiming on zone 1. If after pressing and holding a button, the keypad emits a
confirmation beep, this means the chime feature has been enabled for that zone. If the keypad emits a rejection beep, this
means the chime feature has been disabled for the corresponding zone.
16-Zone LED Keypad:
Press and hold the
[9]
button. Enter the 2-digit (
01 to 16
) zone number(s). When the corresponding LED is on, the zone is
chimed. When the corresponding LED is off, the zone is unchimed. When the desired zones are chimed, press
[
ENTER
]
.
LCD Keypad:
Press and hold the
[9]
button. Enter the 2-digit (
01 to 16
) zone number(s), or use the arrow keys to scroll through the zones.
and when the appropriate zone is displayed, press the
[
FNC1
]
button. When the desired zones are chimed, press
[
ENTER
]
.
KEYPAD MUTING
Press and hold the
[
CLEAR
]
button for 3 seconds to enable or disable keypad muting. When muted, the keypad will only “beep”
when a button is pressed or when the keypad emits a rejection or confirmation beep. All other “beep” functions are disabled.
QUICK FUNCTION KEYS
Installer Test Mode
[
ENTER
] + [
INSTALLER
CODE
] + [
TBL
] or [
TRBL
]
The Installer Test Mode allows you to perform walk tests where the bell/siren will squawk once to indicate an open zone
and twice to indicate a closed zone. To enter this mode, press [
ENTER
] + [
INSTALLER
CODE
] + [
TBL
] or [
TRBL
]. The keypad will
emit a confirmation beep. To disable this mode, press the [
TBL
] or [
TRBL
] key again. The keypad will emit a rejection beep.
Test Report
[
ENTER
] + [
INSTALLER
/
MASTER
CODE
] + [
MEM
]
Sends the "Test Report" report code programmed in section [211] to the central station.
Call WinLoad Software
[
ENTER
] + [
INSTALLER
/
MASTER
CODE
] + [
BYP
]
This feature is used to establish communication between the control panel and a computer using the WinLoad Software.
After entering this mode the control panel will dial the telephone number programmed in section [150].
Cancel Communication
[
ENTER
] + [
INSTALLER
/
MASTER
CODE
] + [
STAY
]
Cancels all communication until the next reportable event. If the Master Code was used, only communication with
WinLoad would be cancelled.
Answer WinLoad Software
[
ENTER
] + [
INSTALLER
/
MASTER
CODE
] + [
FORCE
]
Forces the control panel to pick-up an incoming telephone call.