32
Programming Guide
INSTANT ARMING
After
Stay Arming
the system and
during its
Exit Delay
,
press and hold the
[
STAY
]
button for 3 seconds
.
You should hear a
"
CONFIRMATION
BEEP
". This will switch all armed zones to
Instant zones
.
If you have access to both partitions:
To Instant Arm one partition, press [
STAY
] + [
ACCESS
CODE
] + [
SELECT
PARTITION
] + [
CLEAR
] + press & hold [
STAY
]
To Instant Arm both partitions, press [
STAY
] + [
ACCESS
CODE
] + [1] + [2] + press & hold [
STAY
]
FORCE ARMING
Force Arming
allows users to rapidly arm the system, without having to wait for all zones in the system to be closed.
Force Arming
is commonly used when a motion detector is protecting the area occupied by a keypad. Therefore, when arming the system, if the
motion detector is set as a
Force Zone
, the control panel will ignore the zone and allow users to arm the system even if the zone
is open. Any open
Force Zones
at the time of arming will be considered "deactivated" by the control panel. If during this period a
"deactivated" zone is closed, the control panel will revert that zone to "active" status, hence, will generate an alarm if breached.
If you make a mistake, the keypad will emit a "
REJECTION
BEEP
". When correctly
Force Armed
, the appropriate "
ARM
"
indication will appear and the
Exit Delay
will be initiated. Please note that
Force Arming
can also be activated using
One-
Touch Force Arming
. Also note that the
Access Code
must have the
Force Arming Option
enabled.
MANUAL BYPASS PROGRAMMING
Manual Bypass Programming
allows users to program the alarm system to ignore ("deactivate") specified zones the next
time the system is armed. Please note that
Fire Zones
can not be bypassed and that
Manual Bypass Programming
can also
be activated using
One-Touch Bypass Programming
.
*If you have access to both partitions, press the button corresponding to the desired
partition. The
Access Code
must have the
Bypass Programming Option
enabled.
How Do I Force Arm?
1) All zones in the desired partition (except
Force Zones
) must be closed.
2) Press the
[
FORCE
]
button
3) Key in a valid
[
ACCESS
CODE
]
IF YOU HAVE ACCESS TO BOTH PARTITIONS:
4) Press the button corresponding to the partition you wish to
Arm.
To
Arm
both partitions, press the
[1]
key then after the confirmation beep
press the
[2]
key.
How do I Program Bypass Entries?
1) Press the
[
BYP
]
button.
2) Key in a valid
[
ACCESS
CODE
]*
3) Select one or more
[
ZONES
]
you wish to bypass
4) Once you have entered the desired bypass entries, press the
[
ENTER
]
button to accept these entries.