76
Aquarea air-to-water heat pumps - Planning and installation manual - 02/2022
Product Description
4
2
3
1
4
A
5
6
7
A Internal view
1 Thermometer
2 Cover of electric tank heater (Ø 180 mm)
3 Adjustable foot (x 3, 120° angle)
4 Sacrificial magnesium anode
5 Heat insulation (50 mm thick)
6 Hot water tank
7 Heat exchanger coil
PAW‑TA20C1E5STD / PAW‑TA30C1E5STD / PAW‑TA40C1E5STD
Connections
a
d
b
e
c
f
B
2
1
b
c
d
e
f
A
a
A Top view for floor-standing installation
1 Detail view of water piping connections on top side
B Bottom view for wall‑mounted installation
2 Detail view of water piping connections on bottom side
Connection
PAW‑TA15C1E5STD
a
Air purge outlet
G 1/2”
b
Hot water outlet
G 3/4”
c
Return water outlet to the heat pump
G 3/4”
d
Fresh water inlet
G 3/4”
e
Supply water inlet from the heat pump
G 3/4”
f
Circulation pipe inlet
G 3/4”
Unit: Inches (")
PAW‑TA15C1E5STD
a
A
c
b
d
e
f
Connection
PAW‑
TA20C1E5STD
PAW‑
TA30C1E5STD
PAW‑
TA40C1E5STD
a
Thermometer
G 1/2”
G 1/2”
G 1/2”
b
Hot water outlet
G 1”
G 1”
G 1”
c
Supply water inlet
from the heat pump
G 1”
G 1”
G 1”
d
Circulation pipe inlet
G 3/4”
(160 – 400 l),
G 1” (500 l)
G 3/4”
(160 – 400 l),
G 1” (500 l)
G 3/4”
(160 – 400 l),
G 1” (500 l)
e
Return water outlet to
the heat pump
G 1”
G 1”
G 1”
f
Fresh water inlet
G 1”
G 1”
G 1”
Unit: Inches (")