51
Aquarea air-to-water heat pumps - Planning and installation manual - 02/2022
Product Description
4
Bi-bloc systems | Aquarea HT | F Generation | Single Phase / Three Phase | Heating Only | R407C
Single phase (Power to indoor)
Three phase (Power to indoor)
Kit
KIT‑WHF09F3E5
KIT‑WHF12F6E5
KIT‑WHF09F3E8
KIT‑WHF12F9E8
Heating capacity / COP (A +7 °C, W 35 °C)
kW / COP
9,00 / 4,64
12,00 / 4,46
9,00 / 4,64
12,00 / 4,46
Heating capacity / COP (A +7 °C, W 65 °C)
kW / COP
9,00 / 2,48
12,00 / 2,41
9,00 / 2,48
12,00 / 2,41
Heating capacity / COP (A +2 °C, W 35 °C)
kW / COP
9,00 / 3,45
12,00 / 3,26
9,00 / 3,45
12,00 / 3,26
Heating capacity / COP (A +2 °C, W 65 °C)
kW / COP
9,00 / 2,06
10,30 / 2,01
9,00 / 2,06
10,30 / 2,01
Heating capacity / COP (A -7 °C, W 35 °C)
kW / COP
9,00 / 2,74
12,00 / 2,52
9,00 / 2,74
12,00 / 2,52
Heating capacity / COP (A -7 °C, W 65 °C)
kW / COP
9,00 / 1,79
9,60 / 1,77
9,00 / 1,79
9,60 / 1,77
ErP data for Space Heating
Average climate
Seasonal energy efficiency (ηs,h)
W35 / W55
%
153 / 125
150 / 125
153 / 125
150 / 125
SCOP
W35 / W55
3,90 / 3,20
3,82 / 3,21
3,90 / 3,20
3,82 / 3,21
Energy class
1
W35 / W55
A++ / A++
A++ / A++
A++ / A++
A++ / A++
Warm climate
Seasonal energy efficiency (ηs,h)
W35 / W55
%
191 / 156
188 / 156
191 / 156
188 / 156
SCOP
W35 / W55
4,84 / 3,97
4,77 / 3,97
4,84 / 3,97
4,77 / 3,97
Energy class
1
W35 / W55
A+++ / A+++
A+++ / A+++
A+++ / A+++
A+++ / A+++
Cold climate
Seasonal energy efficiency (ηs,h)
W35 / W55
%
137 / 116
134 / 113
137 / 116
134 / 113
SCOP
W35 / W55
3,50 / 2,97
3,42 / 2,90
3,50 / 2,97
3,42 / 2,90
Energy class
1
W35 / W55
A+ / A+
A+ / A+
A+ / A+
A+ / A+
Indoor unit
WH‑SHF09F3E5
WH‑SHF12F6E5
WH‑SHF09F3E8
WH‑SHF12F9E8
Sound pressure
dB(A)
33
33
33
33
Dimension
H x W x D
mm
892 x 502 x 353
892 x 502 x 353
892 x 502 x 353
892 x 502 x 353
Net weight
kg
46
47
47
48
Water pipe connector
Inch
R 1¼
R 1¼
R 1¼
R 1¼
A class pump
Number of speeds
7
7
7
7
Input power (Min / Max)
W
38 / 100
40 / 106
38 / 100
40 / 106
Heating water flow (∆T=5 K. 35 °C)
L/min
25,8
34,4
25,8
34,4
Capacity of integrated electric heater
kW
3
6
3
9
Recommended fuse
A
30 / 30
30 / 30
30 / 16
30 / 16
Recommended cable size, supply 1 / 2
mm²
3 x 4,0 or 6,0 / 3 x 4,0
3 x 4,0 or 6,0 / 3 x 4,0
5 x 1,5 / 3 x 1,5
5 x 1,5 / 5 x 1,5
Outdoor unit
WH‑UH09FE5
WH‑UH12FE5
WH‑UH09FE8
WH‑UH12FE8
Sound power
1)
dB(A)
—
—
—
—
Dimension
H x W x D
mm
1 340 x 900 x 320
1 340 x 900 x 320
1 340 x 900 x 320
1 340 x 900 x 320
Net weight
kg
104
104
110
110
Refrigerant (R407C) / CO
2
Eq.
kg / T
2,90 / 5,145
2,90 / 5,145
2,90 / 5,145
2,90 / 5,145
Pipe diameter
Liquid / Gas
Inch (mm)
3/8 (9,52) / 5/8 (15,88)
3/8 (9,52) / 5/8 (15,88)
3/8 (9,52) / 5/8 (15,88)
3/8 (9,52) / 5/8 (15,88)
Pipe length range
m
3 ~ 30
3 ~ 30
3 ~ 30
3 ~ 30
Elevation difference (in/out)
m
20
20
20
20
Pipe length for additional gas
m
10
10
10
10
Additional gas amount
g/m
70
70
70
70
Operation range
Outdoor ambient
Heat
°C
-20 ~ +35
-20 ~ +35
-20 ~ +35
-20 ~ +35
Water outlet
Heat
°C
25 ~ 65
25 ~ 65
25 ~ 65
25 ~ 65
1 Scale from A+++ to D.
2 Sound power in accordance to 811/2013, 813/2013 and EN12102-1:2017 at +7 °C.
Note:
EER and COP calculation is based in accordance to EN14511.
4.6.3
Mono-bloc system
The mono-bloc system consists of one single unit that is installed outdoors and can be connected
directly to the heating circuit. The operation is effected via wired remote controller inside the
building.