120
Aquarea air-to-water heat pumps - Planning and installation manual - 02/2022
Planning
5
Bi-bloc systems with hydrokit
Models
Power supply 1
Power supply 2
Phases
Max. current
consumption
(A)
Max. power
consumption
(kW)
Min. cable size
(mm²)
Phases
Max. current
consumption
(A)
Max. power
consumption
(kW)
Min. cable size
(mm²)
WH-SDC03
WH-UD03JE5
1
12.0
2.59
3 x 1.5
1
13.0
3.0
3 x 1.5
WH-SDC03
WH-UD05JE5
1
12.0
2.59
3 x 1.5
1
13.0
3.0
3 x 1.5
WH-SDC07
WH-UD07JE5
1
15.9
3.47
3 x 2.5
1
13.0
3.0
3 x 1.5
WH-SDC07
WH-UD09JE5-1
1
15.9
3.47
3 x 2.5
1
13.0
3.0
3 x 1.5
WH-SDC
WH-UD12HE5
1
24.0
5.30
3 x 4.0
1
26.0
6.0
3 x 4.0
WH-SDC
WH-UD16HE5
1
26.0
5.74
3 x 4.0
1
26.0
6.0
3 x 4.0
WH-SXC
WH-UX09HE5
1
29.0
6.27
3 x 4.0
1
13.0
3.0
3 x 4.0
WH-SXC
WH-UX12HE5
1
29.0
6.27
3 x 4.0
1
26.0
6.0
3 x 4.0
WH-SHF
WH-UH09FE5
1
28.5
6.09
3 x 4.0 or
3 x 6.0
1
13.0
3.0
3 x 4.0
WH-SHF
WH-UH12FE5
1
29.0
6.20
3 x 4.0 or
3 x 6.0
1
26.0
6.0
3 x 4.0
RCCB and power supplies
Indoor unit / outdoor unit connection
L
N
L
N
L
1
N
1
L
1
N
1
1
2
3
1
2
3
3
3
r
L
N
L
N
L
1
N
1
L
1
N
1
1
2
3
1
2
3
3
3
r
RCCB
Power supplies
L
N
L
N
L
1
N
1
L
1
N
1
1
2
3
1
2
3
3
3
r
Power supply 1 Power supply 2
2
3
1
2
3
1
2
3
L
N
L
N
L
1
N
1
L
1
N
1
Terminal block
Indoor unit / outdoor unit
Connection of indoor unit
and outdoor unit
1
2
3
1
2
3
L
N
L
N
L
1
N
1
L
1
N
1
1
2
Terminals on indoor unit
Terminals on outdoor unit
Terminals on disconnector of the power supply
1
2
3
Models
Power supply 1
Power supply 2
Phases
Max. current
consumption
(A)
Max. power
consumption
(kW)
Min. cable size
(mm²)
Phases
Max. current
consumption
(A)
Max. power
consumption
(kW)
Min. cable size
(mm²)
WH-SDC
WH-UD09HE8
3
13.1
8.85
5 x 1.5
1
13.0
3.0
3 x 1.5
WH-SXC
WH-UX09HE8
3
14.7
9.85
5 x 1.5
1
13.0
3.0
3 x 1.5
WH-SQC
WH-UQ09HE8
3
14.7
9.85
5 x 1.5
1
13.0
3.0
3 x 1.5
WH-SHF
WH-UH09FE8
3
14.5
9.67
5 x 1.5
1
13.0
3.0
3 x 1.5