154
Aquarea air-to-water heat pumps - Planning and installation manual - 02/2022
Installation
6
Drilling template for outdoor units and mono-bloc units
Aquarea High Performance bi-bloc outdoor unit | 3 and 5 kW
WH-UD03JE5, WH-UD05JE5
Aquarea High Performance bi-bloc outdoor unit | 9 and 7 kW
WH-UD07JE5, WH-UD09JE5-1
37
622
(23)
69
61
298
823,4
21,9
160
540
53,4
68,5
(124)
32
97
167
330
391
900
110
320
318,5
355
795
410
0
2
6
)
0
4
1
(
175
140
300
176
24
(10)
(30)
DD
(30)
(10)
320
20
(15)
40
400
Aquarea High Performance, T-CAP and HT bi-bloc outdoor
unit | 9 to 16 kW
WH-UD**HE5, WH-UD**HE8, WH-UX**HE5, WH-UX**HE8,
WH-UH**FE5, WH-UH**FE8
T-CAP Super Quiet bi-bloc outdoor unit | 9 to 16 kW
WH-UQ**HE8
40
1340
320
900
620
(140)
140
355
400
320
40
(20)
(579)
40
0
35
6
141
0
61
5
42
6,5
70
32
0
152
1283
318,5
30
c
50
17
5
27
5
41
3
45
45
45
83,5
Aquarea High Performance mono-bloc unit | J generation | 5 to
9 kW
WH-MDC**J3E5
Aquarea High Performance, T-CAP and HT mono-bloc unit | 9
to 16 kW
WH-MDC**H6E5, WH-MXC**J3E5, WH-MXC**J*E8, WH-
MXC**H3E5, WH-MXC**H*E8, WH-MHF**G*E5
(579)
0
8
9
2
5
1
1283
319
86
5
48
0
70
(1
0)
(1
0)
(20)
152
40
0
35
5
32
0
(10)
(579)
40
0
35
6
141
0
61
5
42
6,5
70
32
0
152
1283
318,5
30
c
50
17
5
27
5
41
3
45
45
45
83,5
When fastening the outdoor unit or mono-bloc unit to a base frame or a bracket on the building
outer wall, vibration dampers must be mounted under the device. When fastening on a concrete
foundation, it is advisable to use vibration dampers.
In the case of installation locations experiencing strong winds e.g. on building rooftops or between
buildings, the outdoor unit or mono-bloc unit must be additionally secured in the field to prevent