![background image](http://html1.mh-extra.com/html/panasonic/wh-adc0309j3e5/wh-adc0309j3e5_planning-and-installation-manual_3510013168.webp)
168
Aquarea air-to-water heat pumps - Planning and installation manual - 02/2022
Installation
6
Connections of the water pipes – All in One unit | J and H generation | Compact
configuration (for 1 heating zone)
WH-ADC0309J3E5C, WH-ADC1216H6E5C
a b
c d
a Supply water outlet (to space heating/cooling)
b Return water inlet (from space heating/cooling)
c Fresh water inlet
d Supply water outlet (to hot water tank)
Connections of the water pipes – All in One unit | H generation | Standard configuration (for
1 heating zone)
WH-ADC1216H6E5, WH-ADC0916H9E8
d
c
b
a
a Supply water outlet (to hot water tank)
b Fresh water inlet
c Supply water outlet (to space heating/cooling)
d Return water inlet (from space heating/cooling)