88
Aquarea air-to-water heat pumps - Planning and installation manual - 02/2022
Product Description
4
The ventilation unit provides fresh filtered outside air to a residential building while keeping a high
thermal comfort within the building by using the exhaust indoor air to precondition the incoming air,
leading to lower heating requirements in the building. To this end, the unit is equipped with a highly
energy-efficient rotary heat exchanger with EC technology fans.
For a space-saving solution, the compact ventilation unit is optimised for installation atop the
Panasonic Square Tank (PAW-TA20C1E5C) or the Aquarea All in One Compact indoor units (WH-
ADC0309J3E5C, WH-ADC1216H6E5C). However, it can also be combined with Aquarea mono-
bloc or bi-bloc systems. In all these cases, the residential ventilation unit and the Aquarea heat
pump can be controlled with one single user-friendly controller.
The residential ventilation unit is available in two versions: with the supply air connection on the
left-hand side (PAW-A2W-VENTA-L) or on the right-hand side (PAW-A2W-VENTA-R).
i
Note
When installing a residential ventilation unit, observe the respective installation instructions
enclosed with each model. The installation instructions may contain important information about
additional accessories, which are needed for the installation and which must be provided by the
client.
Components
1 2
3
4
A
9
10
8
6
7
5
A Internal view (seen from front side)
1 Supply air sensor (only visible from top)
2 Rotating heat exchanger
3 Drive belt for rotating heat exchanger
4 Cable glands for external PCB connections
5 Outdoor air sensor
6 Supply air filter
7 Exhaust air fan
8 Main printed circuit board (PCB)
9 Relative humidity/Extract air temperature sensor
10 Exhaust air filter
Note: Internal view of PAW-A2W-VENTA-L shown as an example.
Duct connections
b
c
a
d
A
d
a
c
b
B
A PAW‑A2W‑VENTA‑
L
B PAW‑A2W‑VENTA‑
R
Duct connection
Diameter
a
Supply air connection
125
b
Return air connection
125
c
Exhaust air connection
125
d
Outdoor air connection
125
Unit: mm
PAW‑A2W‑VENTA‑
L
PAW‑A2W‑VENTA‑
R