25
Aquarea air-to-water heat pumps - Planning and installation manual - 02/2022
Product Description
4
Aquarea High Performance
Aquarea T‑CAP
Aquarea HT
Control and connectivity
Smart Grid Contact
6
Wireless LAN Ready
Smart Grid Contact
6
Wireless LAN Ready
Smart Grid Contact
6
Range
All in One from 3 to 16 kW (185 L)
Bi-bloc from 3 to 16 kW
Mono-bloc from 5 to 9 kW
All in One from 9 to 16 kW (185 L)
Bi-bloc from 9 to 16 kW
Mono-bloc from 9 to 16 kW
Bi-bloc from 9 to 12 kW
Mono-bloc from 9 to 12 kW
Note: All data in this chart is applicable in most of models in each line up, check product specs to confirm.
1
Scale from A+++ to D
2
9 and 12 kW
3 DHW maximum temperature with heater.
4
In case of outdoor temperature over -10 °C.
5
It is possible to set temperature to 65 °C on remote controller. Normally, outlet water temperature is 60 °C or lower. In
case of ΔT setting with remote controller is 15 °C and the outdoor ambient temperature is 5 to 20 °C, outlet water tem
-
perature 65 °C is possible.
6
J and H Generation with CZ-NS4P, F and G Generation with Heat Pump Manager.
Besides the notable differences as in mono-bloc and bi-bloc systems or hydrokit and All in One
unit, all models have the same working principle and can therefore be described together in respect
of many planning-relevant properties. The relevant differences, even those between different
product generations, will be pointed out at the appropriate point.
4.5.3 Model code
For easy and clear denomination of the different Aquarea models, a model code is used, from
which the models with their respective specific properties and functions can be read off.
Example
WH-MDC05J3E5 is a heat pump unit (WH-) in mono-bloc design (M) of the High Performance
series (D) with cooling function (C), a nominal power of 5 kW (05) of the J generation (J) for the
European market (E) with a single phase power supply (5).
Model code for All in One indoor units (bi-bloc systems)
Device type
WH
: Air-to-water
heat pump
Construction
A
: All in One indoor unit (hydrokit and
hot water tank of the bi-bloc systems)
Series
D
: Aquarea High Performance / Aquarea T-CAP
Operating mode
C
: Heating and cooling
Nominal
heating capacity
1
0309
: 3, 5, 7 or 9 kW,
0916
: 9, 12, or 16 kW,
1216
: 12 or 16 kW
Device
generation
2
... H, J ...
Backup heater
capacity
3
: 3 kW,
6
: 6 kW,
9
: 9 kW
Market
E
: Europe
Power supply
5
: Single phase,
8
: Three phase
Model type
B
: Two-zone model with additional equipment for 2nd heating circuit integrated,
C
: Compact configuration
WH
‑
A
D
C
0309
J
3
E
5
C
1
The available capacities differ according to the series. An overview is given in the model range (→
).
2
J generation requires refrigerant R32, H generation requires refrigerant R410A.