6.2 Specifications, Controller ST4-C12EX
Item
Description
Supply voltage
24V DC
+10
-15
% Ripple P-P 10% or less
Current consumption
0.12A or less
PNP or NPN open-collector transistor. Select PNP or NPN output with switch.
PNP output
•
Max. source current: 200mA
•
Applied voltage: same as the supply voltage (between control
output and +V)
•
Residual voltage: 2.5V or less (at 200mA source current)
•
Leakage current: 200µA or less (also in power OFF state)
•
Maximum load capacity: 1µF (with or without load)
•
Load wiring resistance: 3
Ω
or less
NPN output
•
Max. 200mA sink current
•
Applied voltage: same as the supply voltage (between control
output and 0V)
•
Residual voltage: 2.0V or less (at 200mA sink current)
•
Leakage current: 200µA or less (also in power OFF state)
•
Maximum load capacity: 1µF (with or without load)
•
Load wiring resistance: 3
Ω
or less
Output operation
•
ON when all beams of the connected ST4-A
□
s are received.
•
OFF when one or more beams of the connected ST4-A
□
s are
interrupted (except during muting)
Short circuit
protection
Incorporated
Control output
OSSD1/2 (Note 1)
Response time
•
Turn-off time: 25ms or less
•
Turn-on time: 90ms or less (auto-reset)/140ms or less (manual
reset)
PNP or NPN open-collector transistor. Select PNP or NPN output with switch.
PNP output
•
Max. source current: 100mA
•
Applied voltage: same as the supply voltage (between auxiliary
output and +V)
•
Residual voltage: 2.5V or less (at 100mA source current)
NPN output
•
Max. 100mA sink current
•
Applied voltage: same as the supply voltage (between auxiliary
output and 0V)
•
Residual voltage: 2.0V or less (at 100mA sink current)
Auxiliary output (Note
1)
Output operation
Auxiliary output 1
ON when muting function is disabled
OFF when muting function is enabled
Auxiliary output 2
ON when override function is disabled
OFF when override function is enabled
Auxiliary output 3
ON when muting lamp is in normal condition
Rugghölzli 2