![Panasonic ST4 Series Instruction Manual Download Page 92](http://html.mh-extra.com/html/panasonic/st4-series/st4-series_instruction-manual_278037092.webp)
Troubleshooting
Panasonic ST4 Instruction Manual
84
Symptom
Cause
Remedy
Control output (OSSD 1/2) short-circuits
with +V or 0V.
The PNP/NPN settings of the output
polarity selection switch and the control
output (OSSD 1/2) do not match.
Check the output polarity selection switch.
Wire the control output (OSSD 1/2) wires
correctly (see page 36).
1
Output circuit error.
Output circuit is damaged.
Replace the ST4-C12EX.
Excessive incoming current flows in the
control output (OSSD 1/2).
Current value should be within the specified
control output (OSSD 1/2).
For details, see "Specifications, Controller
ST4-C12EX" on page 90.
Control output (OSSD 1/2) short-circuits
with +V or 0V.
Wire the control output (OSSD 1/2) wires
correctly (see page 36).For details, refer to
Wiring (see page 36).
The PNP/NPN settings of the output
polarity selection switch and the control
output (OSSD 1/2) do not match.
Check the output polarity selection switch.
Wire the control output (OSSD 1/2) wires
correctly (see page 36).
Fault display:
•
Control
output
(OSSD 1/2) error
2
Output circuit error.
Output circuit is damaged.
Replace the ST4-C12EX.
Fault display:
•
Extraneous
light
error
Extraneous light is entering or light from
other ST4-A
□
is entering.
When the power is ON, prevent any extraneous
light from entering the receiver.
If the extraneous light is coming from ST4-A
□
,
execute the interference prevention function see
"Interference Prevention Function" on page 54.
In case of ST4-A
□
V, execute the emission
amount adjustment function (see page 57) as
well.
If the error could not be resolved, contact our
office.
Muting lamp terminals short-circuit.
Muting lamp output short-circuits with
other I/O wires.
Wire the muting lamp correctly (see page 36).
Excessive incoming current flows in the
muting output.
Current value should be within the specification
of muting lamp.
For details, see "Specifications, Controller
ST4-C12EX" on page 90.
Fault display:
•
Muting lamp error
Output circuit error.
Output circuit is damaged.
Replace the ST4-C12EX.
Fault display:
•
Reset
error
Voltage level of reset input signal is
unstable.
Wire the reset input terminals correctly (manual
reset: between X1 and X2, or auto reset:
between X1 and X3).
Output polarity
was changed
during operation of
the device.
Turn OFF the power of the device and change
the output polarity.
Fault display:
•
Switch
setting
error
Output polarity
selection switch
(PNP/NPN setting)
Switch is broken.
Replace the ST4-C12EX.
Rugghölzli 2
CH - 5453 Busslingen
Tel. +41 (0)56 222 38 18
Fax +41 (0)56 222 10 12
www.sentronic.com
Produkte, Support und Service
SENTRONIC