2.2.3 Elements of the Sensor ST4-A
Emitter Receiver
2
1
3
2
4
Identifier
Function
1
Beam
emission
indicator
(Green)
Lights up during beam emission of the sensor.
Turns off during emission halt of the sensor.
2
Beam
interruption
indicator
(Red)
Lights up during beam interruption of the sensor.
Lights up during lock out.
Turns off during beam reception of the sensor.
3
Emission
amount
adjuster
(Note 1)
Adjusts the emission amount.
For details, refer to Operation Test (see page 46) or Emission Amount Adjustment
Function (see page 57).
4
Stable
incident
beam
indicator
(Green)
Lights up when incident beam intensity is over 150%. (Note 2)
Turns off when incident beam intensity is 150% or less. (Note 2)
NOTE
1. Only available with the ST4-A
□
V type.
2. The incident beam intensity that turns the control output (OSSD 1/2) to ON is
regarded as 100%.