![Panasonic ST4 Series Instruction Manual Download Page 65](http://html.mh-extra.com/html/panasonic/st4-series/st4-series_instruction-manual_278037065.webp)
Panasonic ST4 Instruction Manual
3.5 Auxiliary Output
57
Time chart for manual reset
ON
OFF
20ms or less
20ms or less
90ms or less
20ms or less
ON
OFF
Beam
received
Beam
interrupted
Auxiliary output
(Negative logic
of OSSD)
Control output
(OSSD 1 / 2)
Reception
status
Time chart for auto-reset
3.5.3 Emission Amount Adjustment Function
!
DANGER!
The emission amount adjuster of the ST4-A
□
V is used to
reduce the beam emission of the ST4-A
□
V to prevent
influencing other sensors.
Do not use the emission amount adjuster of the ST4-A
□
V to
prevent the reflection off surfaces. If it is used for such
purposes and the emission amount adjuster is set at MAX.,
the reflection off surfaces increases. This may disable the
sensor from detecting objects, which could result in serious
injury or death.
To cope with reflective surfaces, see "Influence of Reflective
Surfaces" on page 20 .
This function is incorporated in the ST4-A
□
V. It is used to reduce the emission amount so that
the emitted beam of ST4-A
□
V will not be received as extraneous light from the other sensors.
The emission amount can be reduced by turning the emission amount adjuster on the emitter of
ST4-A
□
V to the MIN. side.
Rugghölzli 2
CH - 5453 Busslingen
Tel. +41 (0)56 222 38 18
Fax +41 (0)56 222 10 12
www.sentronic.com
Produkte, Support und Service
SENTRONIC
AG