3.8 Muting Pattern Selection Function (Only ST4-C12EX)
67
3.8 Muting Pattern Selection Function (Only ST4-C12EX)
The muting pattern selection function is incorporated only in ST4-C12EX.
The ST4-C12EX presets the muting patterns complying with ISO 12643 (Safety requirements
for graphic technology equipment and systems).
The muting pattern and the valid time of the muting/override can be set with the setting switches
"SW 1 to 4."
CAUTION
Make sure to turn off the power to set the muting pattern. If you set the muting
pattern while power is on, it will be invalid.
Valid time
Muting
Override
Muting
Override
Muting
pattern no.
180s
60s
No time
restriction
600s
1
2
3
NOTE
If other settings than the preceding muting patterns are chosen, the device will
switch into lockout state, and an error will be indicated on the fault display (red).