Before Using this Device
Panasonic ST4 Instruction Manual
30
2.4.2 Mounting the Sensor ST4-A
□
Select the sensor mounting bracket based on the installation environment. The mounting
bracket is not included with this device. Please purchase the optional sensor mounting bracket
that fits with the mounting environment.
!
DANGER!
After installing the ST4-A
□
, check that the ST4-A
□
detects a part
of human body before it reaches to the dangerous part of the
machine, by watching the beam interruption indicator (red).
Also check that ST4-A
□
is installed in a proper position.
CAUTION
•
Do not apply an improper load such as forcibly bending the cable of the
single-beam sensor, because the wire could break.
•
The minimum bending radius of the cable is R5mm. When mounting,
consider the cable bending radius.
NOTE
•
Mount the emitter and the receiver at the same level and parallel to each
other. The effective aperture angle of this device is ±2.5° or less for a sensing
distance of 3m or more.
•
In preparation for mounting, prepare mounting holes on the mounting
surface (see "Dimensions" on page 95).
The following procedure shows the mounting of the single-beam sensor with the mounting
bracket MS-CX1.
1.
2.
3.
Procedure
1. Mount the sensor with the M3 screws with washers (length 12mm) attached
to the sensor mounting bracket (optional).