![Panasonic ST4 Series Instruction Manual Download Page 23](http://html.mh-extra.com/html/panasonic/st4-series/st4-series_instruction-manual_278037023.webp)
Panasonic ST4 Instruction Manual
2.3 Protection Area
15
2.3 Protection Area
2.3.1 Sensing
Range
!
DANGER!
Be sure to install a protective structure around the machine so
that the operator must pass through the sensing area of the
single beam sensor to reach the dangerous parts of the machine.
Failure to do so can result in death or serious injury.
Do not use any reflection type or recursive reflection type
arrangement.
Installing multiple sets of this device produces a non-sensing
area or causes mutual interference, which may result in death or
serious injury.
This example shows what a protective structure could be, where the dangerous part of a
machine should be situated and how the emitter and receiver can be arranged.
EXAMPLE
Installing four units of the ST4-A
□
300mm
300mm
300mm
300mm
ST4-A
□
ST4-A
□
Dangerous
part
Emitter of the
Receiver of the
Protective structure
Rugghölzli 2
CH - 5453 Busslingen
Tel. +41 (0)56 222 38 18
Fax +41 (0)56 222 10 12
www.sentronic.com
Produkte, Support und Service
SENTRONIC