64
-
IEC 61496-1 (UL 61496/JIS B 9704-1): 'Safety of machinery - Electro
sensitive protective equipment - Part 1: General requirements and tests'
Annex A, A.7 Muting
-
IEC 60204-1 (JIS B 9960-1): 'Safety of machinery - Electrical equipment of
machines - Part 1: General requirements, 9.2.4 Overriding safeguards'
-
EN 415-4: 'Safety of packaging machines part 4. Palletizers and
depalletizers' Annex A, A2.2 Muting'
-
ANSI B11.19-1990: 'for Machine Tools-Safeguarding When Referenced by
the Other B11 Machine Tool Safety Standards-Performance Criteria for
the Design, Construction, Care, and Operation' 4.2.3 Presence-Sensing
Devices: Electro-Optical and Radio Frequency (R.F.)
-
ANSI/RIA R15.06-1999: 'for Industrial Robots and Robot Systems - Safety
Requirements, 10.4.5 Muting'
The override function is active when all the conditions listed as follows are satisfied:
•
The incandescent lamp with 1 to 10W is connected to the muting lamp output.
•
The override signal is input from either or both of the muting inputs between S-A and
S-B (between S-C and S-D, or S-E and S-F)
•
Both the emission halt input shall be opened and the override input shall be
short-circuited within 1 second (3 sec. continuously).
If any of these three conditions is not satisfied or takes longer than the valid muting/override
time of 60 or 600 seconds, the override function becomes inactive (see "Muting Pattern
Selection Function (Only ST4-C12EX)" on page 67).