![Panasonic ST4 Series Instruction Manual Download Page 18](http://html.mh-extra.com/html/panasonic/st4-series/st4-series_instruction-manual_278037018.webp)
Before Using this Device
Panasonic ST4 Instruction Manual
10
Part name
Part
(optional)
Branch cable
ST4-CCJ-WY (optional)
Slit mask (optional)
2.2.1 Elements of the Controller ST4-C11
1
2
3
4 5 6 7 8
9
Identifier
Function
1
Emitter connector
Connects the emitter of the ST4-A
□
.
2
Receiver connector
Connects the receiver of the ST4-A
□
.
3
Output polarity selection switch
Switches the control output to PNP output or NPN output.
4
Power indicator (Green)
Lights up while power is ON.
5
Control output indicator (Green)
Lights up while the control output (OSSD 1/2) is ON.
6
Interlock indicator (Yellow)
Lights up while the interlock is ON.
Turns OFF when an error occurs or the control output (OSSD
1/2) is ON.
7
Emission halt indicator (Orange)
Lights up while the emission halt function is valid.
8
Fault indicator
Lights up or blinks when an error occurs.
For details, refer to "Troubleshooting (see page 79)".
9
Terminal block
See the following table.
Terminal block
Terminal name
Description
IL+
IL-
Interference prevention terminals (downstream)
For details, refer to "Interference Prevention Function see "Interference Prevention
Function" on page 54".
IU+
IU-
Interference prevention terminals (upstream)
For details, refer to Interference Prevention Function see "Interference Prevention
Function" on page 54.
Rugghölzli 2
CH - 5453 Busslingen
Tel. +41 (0)56 222 38 18
Fax +41 (0)56 222 10 12
www.sentronic.com
Produkte, Support und Service
SENTRONIC
AG