3.5 Auxiliary Output
The auxiliary output is a non-safety output which is incorporated in the controllers ST4-C11 and
ST4-C12EX. It is reserved for non-safety-related purposes.
3.5.1 Auxiliary
Output
Operation of Controller ST4-C11
Terminal
Auxiliary output operation
AUX
Negative logic of the control output (OSSD 1/2)
3.5.2 Auxiliary
Output
Operation of Controller ST4-C12EX
!
DANGER!
Do not use the auxiliary output to stop the device. The result
could be death or serious injury.
Terminal
Auxiliary output operation
AUX1
ON when the muting function is invalid. OFF when the muting function is valid.
AUX2
ON when the override function is invalid. OFF when the override function is valid.
AUX3
ON when the muting lamp is in the normal condition. OFF when the muting lamp is in an abnormal
condition.
AUX4
Negative logic of the control output (OSSD 1/2)
ON
OFF
20ms or less
20ms or less
120ms or more
20ms or less
140ms or less
Reset input
ON
OFF
Beam
received
Beam
interrupted
Open
0V/+V
Auxiliary output
(Negative logic
of OSSD)
Control output
(OSSD 1 / 2)
Reception
status