28
Function Parameter Table
No.
Parameter
Selections
Function
000 MON/TEL DIAL 1 = Monitor
2 = TEL/DIAL
Selects whether the machine starts to TX
automatically during On-Hook dialing.
Monitor
: Start to TX after pressing START
TEL/DIAL
: Start to TX automatically
001 ALARM STATUS 1 = OFF
2 = Timer (6 sec.)
3 = Constant
Selects the No Paper or No Toner alarm status.
OFF
: Alarm is disabled.
Timer
: Alarm will shut off after 6 seconds.
Constant
: Alarm will not stop until "STOP" is
pressed or the error is cleared/corrected.
002 STOP COMM.
JRNL
1 = Off
2 = On
Selects whether the machine prompts to print the
COMM. Journal when the printout condition is set to
INC and STOP is pressed during communication.
003 CONTINUOUS
POLL
1 = Off
2 = Stn (Tx only)
Selects whether the Continuous Polling feature is
enabled.
Stn
:
Place the document(s) on the ADF then press the
Program Key [P4] to store or add the document(s)
into a polled file. (See Note 4)
004 NUMERIC ID
SET
1 = Off (will not accept)
2 = On (accepts)
Selects whether the machine accepts and allows to
set or change the Numeric ID.
005 Not Used
006 ID DISPLAY
1 = Number (Numeric ID)
2 = Chara (Character ID)
Selects the priority of displaying the ID.
007 JNL COLUMN
1 = Preset station name
2 = Received ID
Selects the contents of the ID to display on the
Journal.
008 MONITOR
1 = Off
2 = On
Selects whether the Monitor is ON/OFF for
monitoring fax signals.
(FOR SERVICE USE ONLY)
009 DC LOOP
1 = Off (Normal)
2 = On (Off Hook)
Selects a false Off Hook state for back to back
communication test.
010 TX LEVEL
00 = 0 dBm
~
15 = -15 dBm
Selects the TX signal output level, 0 to -15 dBm in 1
dBm steps. (Refer to Chapter 4.3)
011 RX LEVEL
1 = -43 dBm
2 = -38 dBm
3 = -33 dBm
4 = -48 dBm
Selects the receiving sensitivity of -33/-38/-43/-48
dBm.
012 DTMF LEVEL
00 = 0 dBm
~
15 = -15 dBm
Selects the DTMF output level, 0 to -15 dBm in 1
dBm steps.
013 G3 RX EQL
1 = 0 dB
2 = 4 dB
3 = 8 dB
4 = 12 dB
Selects the cable equalizer for G3 reception mode,
0dB, 4dB, 8dB or 12dB.
014 G3 TX EQL
1 = 0 dB
2 = 4 dB
3 = 8 dB
4 = 12 dB
Selects the cable equalizer for G3 transmission
mode, 0dB, 4dB, 8dB or 12dB.
Summary of Contents for Panafax UF-580
Page 114: ...E...