22
061
-
A
ADF Door is open.
Door is not firmly closed.
Connectors are not firmly connected.
200
RCV
C
Decoding process is not completed
at the end of phase C.
Defective SC PCB.
212
XMT
RCV
A-E
Interface error occurred between
the CPU and modem.
Modem is defective. (SC PCB)
Software problem occurred. (SC PCB)
301
XMT
RCV
-
System fault.
Software problem occurred. (SC PCB)
331
XMT
C
8-minutes timer error.
(Germany only)
390
STANDBY
RCV
-
Interface error occurred between
the machine and the PC.
Firmware update error.
GDI print error.
(Perform the operation again)
400
XMT
B
T1 timer (35±5 sec.) elapsed
without detecting 300 bps signal.
Wrong number is dialed and the START
button is pushed.
Telephone line is disconnected while
dialing.
SC PCB (Modem) or MJR PCB are
defective.
Receiver is defective. (It may only be
transmitting CED)
401
XMT
B
DCN was returned from receiver
while transmitter is waiting for CFR
or FTT.
Your machine's ID Number is not
programmed.
Possible incompatibility or incorrect
Password.
402
XMT
B
DCN was returned from receiver
while transmitter is waiting for
NSF/DIS.
Receiver working in non-CCITT mode
only. (Possible incompatibility)
403
RCV
(Polling)
B
Transmitter had no polling function. "POLLED=ON" (polling XMT ready) is
not set at the transmitter.
Document to be transmitted is not
placed at the transmitter.
404
XMT
B
Transmitter sent NSS (or DCS)
followed by TCF three times, but
the receiver did not respond. (CFR
or FTT is usually returned)
Receiver is defective. (Modem, MJR
PCB, etc.)
SC PCB or MJR PCB are defective.
Receiver disconnects line during first
NSS (or DCS) is transmitted.
405
XMT
B
Transmitter received FTT after it
transmitted TCF at 2400bps.
Received RTN after
communicating at 2400 bps.
Line quality is poor. (TCF is damaged
due to line noise)
Receiver is defective. (Modem, etc.)
SC PCB or MJR PCB are defective.
406
RCV
(Password
Comm.)
B
XMT-Password mismatched.
RCV-Password mismatched.
Selective RCV incomplete.
XMT, RCV password does not match.
Last 4 digits of TSI does not match with
the last 4 digits of ONE-TOUCH, ABBR
telephone
number.
407
XMT
D
Transmitter received no response
after it transmitted post message,
such as EOP, MPS, EOM, etc...or
received DCN.
Receiver is defective. (No paper, paper
jamming, etc.)
Receiver ceased receiving because of
excessive error. (Line quality is poor)
SC PCB (Modem) or MJR PCB are
defective.
Fax Information Codes
Code
Mode
Phase
Description of Problem
Cause
Summary of Contents for Panafax UF-580