Home sensor homing 3 (Pr40 = 5) (Only for rotation system)
e.g. : When "Pr41 Detects the homing direction in + direction" is set
Homing direction(
+
)
Coordinate system(
+
)
Home
sensor
①
When the starting
point is out of the
home sensor
②
When the starting
point is upon the home
sensor.
Machine 1 rotation
Home
Home
Starting
point
Home
sensor
Starting
point
Set this option when the machine belongs to rotational system and reversing is not desired.
In this mode, the motor always runs in the set homing direction, and the edge of home sensor is detected and
set to the home. (In this case, runs in + direction only with no reversing.)
If a limit sensor in running direction is detected during homing, homing error (E-HO) is found.
Limit sensor homing (Pr40 = 2)
e.g. : When "Pr41 Detects the homing direction in
−
direction" is set.
Homing direction(
−
)
Coordinate system(
+
)
- direction
limit sensor
+ direction
limit sensor
①
When the starting point
is not upon the limit sensor
in
−
direction.
②
When the starting
point is upon the limit
sensor in
−
direction.
Starting
point
Home
Offset
Home
Offset
Starting
point
In using this mode, the motor at the home position is within the limit sensor, therefore be sure to set the home
offset (Pr47). When the offset is set to -100, the point which is moved 100 pulses in + direction as viewed from
the edge of limit sensor in - direction is set to the home. (Set a value of plus and minus opposite to the desired
travel direction as an offset.)