Digital key pad connecting cable
(option)
AC power supply
* It is the maximum length in our
evaluation environment,
it does not guarantee the operation
in customer's use environment.
It cannot be used
simultaneously.
Digital key pad
(option)
Digital display console.
It enables change of
parameter.
Communication software PANATERM for BL
Please download from our web site
Parameter change and control state monitoring
possible.
Motor extension cable
(option)
Select if needed (up to 10 m).*
Personal computer
(Customer preparation)
Gear head
(option)
PC connecting cable
(option)
GV series
Brushless motor
GU series
Brushless amplifier
POWER
If your PC does not have
RS232 port, use RS232-USB
converter.
Noise
filter
Magnetic
contactor
MCCB
System configuration and wiring
System configuration/ general wiring diagram
• Wiring work should be performed by qualified electric construction expart.
• Do not turn on power before finishing wiring, to avoid risk of electric shock.
• For details of options (sold separately), see P.74.
Wiring equipment
• Recommended noise filter
Voltage
Optional part
number (option)
Manufacturer's
part No.
Manufacturer
Single phase 100, 200 V
DV0P4170
SUP-EK5-ER-6
OKAYA ELECTRIC
IND. CO., LTD.
3-phase
DV0PM20042
3SUP-HU10-ER-6
• Selection of Molded Case Circuit Breaker (MCCB), magnetic contactor, and electric wire
(wiring within equipment) (refer to P.64 “Conformance to EC directive and UL standard”
for compatibility with overseas standard.)
Voltage
Capacity
(W)
MCCB
rated
(
current
)
Magnetic
contactor rated
current
(contact structure)
Minimum wire size (mm
2
)
(Wiring within equipment)
Main circuit/
Grounding wire Control circuit
Single phase
100V
50 to 130
5 A
20 A (3P+1a)
0.5 (AWG20)
0.13 (AWG26)
Single phase
200V
50 to 130
5 A
20 A (3P+1a)
0.5 (AWG20)
0.13 (AWG26)
3-phase
200V
50 to 130
5 A
20 A (3P+1a)
0.5 (AWG20)
0.13 (AWG26)
■
Be sure to ground the grounding terminal.
In wiring to power supply (outside of equipment) from MCCB, use an electric wire of 1.6
mm diameter (2.0 mm
2
) or more both for main circuit and grounding. Must be grounded
with resistance less than 100 Ω. Do not tighten the ground wires together, please tighten
them individually.
•
Selection of relay
As for use for control circuit such as control input terminal, use a relay for small signal
(minimum guarantee current 1 mA or less) for preventing poor contact.
<Example>
Panasonic: DS type, HC type, OMRON: G2A type
•
Control Circuit Switch
When using a switch instead of relay, use one for minute current in order to prevent poor
contact.
<Example>
Nihon Kaiheiki Ind.Co.,Ltd: M-2012J-G