14
15
Installation
Cautions for Proper Use
(1) Because the control circuit is sensitive to temperature and impact, read this instruction
manual carefully for proper installation.
(2) The brushless amplifier switches the power element at a high speed to control the
motor. When the motor runs, leaking current will increase, which may activate the
leakage breaker. If this is the case, use a leakage breaker provided with measure
against high frequency for inverter.
(3) To start and stop the brushless motor, use the RUN switch on the front panel or the
RUN command input (see the function of terminal on page 20).
Avoid operating the motor by turning on / off the power supply, since the life of the
internal circuit will be shortened.
Installation of brushless amplifier
• Install the product up and down correctly in the direction shown below.
• Tightening torque of the product mounting screw should be selected appropriately so
as not to be loose or damaged considering the strength of the screw to be used and
the material of the installation destination.
Recommended tightening torque (When install to steel plate with steel screw):
M4 0.8 N
・
m
to
1.2 N
・
m
• In order to cool effectively, please secure ambient space.
• Measure the ambient temperature 50 mm away from the side and bottom of the
brushless amplifier.
If measurement can not be made at 50 mm distance, including when using brushless
amplifiers side by side, measure at the midpoint of the gap between the obstacle and
the brushless amplifier or the gap between the brushless amplifier and the adjacent
brushless amplifier.
When the motor is driven, the brushless amplifier generates heat, but be sure to keep
the temperature within the range including the heat generation.
• Install in an environment where the pollution degree around the product is 2 or less,
such as putting it in a control panel with IP 54 or higher.
Vertical
Location of fixing screw
Location of fixing screw
Caution